Accessories

External ballast resistors

Authorized braking impulse power for COMPAX 2500S with BRM5/01

Unit hardware

10000

1000

Pbdyn / W

F=50

F=10

F=5

F=2

F=1

F=0.5

F: Factor

Cooling down time = F * braking time

Connector

assignment / cable

Technical data

 

 

 

Configuration

 

 

 

and

functions

100

0,0

0,2

0,4

0,6

0,8

1,0

1,2

1,4

1,6

1,8

2,0

2,2

2,4

2,6

2,8

3,0

Braking time / s

Authorised braking impulse power for COMPAX 4500S and

COMPAX 8500S

100000

F: Factor

Cooling down time = F * braking time

 

 

 

 

single pulse

 

 

 

 

 

 

 

 

 

 

10000

 

F=100

 

 

 

 

 

 

 

 

 

 

 

 

 

F=50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

/ W

F=20

 

 

 

 

 

 

 

 

 

 

 

 

 

F=10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pbdyn

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F=5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1000

F=2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F=1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F=0.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0,0

0,2

0,4

0,6

0,8

1,0

1,2

1,4

1,6

1,8

2,0

2,2

2,4

2,6

2,8

3,0

Braking time / s