Appendix

 

 

COMPAX-M/S

Monitoring and limitation characteristics

 

 

 

 

 

 

 

 

 

 

 

No.

Cause

Action

 

Acknow-

Drive

 

 

 

 

 

 

ledge with

volt.-free

 

E23

The current command is not allowed.

Positioning command in the speed control mode.

Quit

no

 

 

 

Approach MZ in speed control mode.

 

 

 

 

 

Travel command when drive is switched off.

 

 

 

 

 

Hand +/- when an error is present.

 

 

 

 

 

More than 8 consecutive comparator commands

 

 

 

 

 

 

(preparatory commands) in the data record

 

 

 

 

 

 

memory.

 

 

 

 

E24

The speed selected is not valid.

Enter speed between 0...100%.

Quit

no

 

E25

The position selected is not valid.

Note end limits and "Software end limit monitoring"

Quit

no

 

 

 

chapter in variant documentation.

 

 

 

E26

REPEAT without END or GOSUB

Insert END / RETURN command.

Quit

no

 

 

without RETURN .

 

 

 

 

 

 

E27

Parameter must not be written.

Check parameter.

Quit

no

 

E29

Motor values missing.

Send unit to HAUSER.

Quit

yes

 

E30

Hardware fault.

Remove extreme external sources of fault.

Quit

yes

 

E31

Error in parameters.

Check parameter.

Quit

no

 

E32

Error in parameters.

Check parameter.

Quit

no

 

E33

Error in program memory.

Check data record memory.

Quit

no

 

E34

Error in program memory.

Check data record memory.

Quit

no

 

E35

Hardware fault.

Remove extreme external sources of fault.

Quit

no

 

E36

Hardware fault.

Faulty or incorrect unit hardware.

Power on

yes

 

E37

Auxiliary voltage +15 V missing.

Switch on again.

 

Power on

yes

 

E38

Voltage in intermediate circuit too

Increase braking and idle times / check mains power.

Quit

yes

 

 

high; e.g. if braking output is too

COMPAX 25XXS: external ballast resistance

 

 

 

 

high. Limits:

missing.

 

 

 

 

 

COMPAX 25XXS: >400V

COMPAX 45XXS/85XXS: bridges X2/5 - X2/6

 

 

 

 

COMPAX 10XXSL: >400V

missing.

 

 

 

 

 

otherwise: >800V

 

 

 

 

 

COMPAX 1000SL: Check value P134.

 

 

 

 

 

 

 

 

E39

Temperature too high (>85°), cycle

Increase acceleration times.

Quit

yes

 

 

too hard.

 

 

 

 

 

 

E40

Input "Enable final stage" (45/85S: X3/1-/2; 1000SL X19/24-X19/12, 35XXM: X19/9-/10) not assigned

Quit

yes

 

 

Only with COMPAX 35XXM, COMPAX 45XXS, COMPAX 85XXS and COMPAX 1000SL!

 

 

 

 

Note!

 

 

 

 

 

 

 

With E40 there is no braking delay; the final stage is immediately switched off.

 

 

 

 

The input has a direct effect on the hardware.

 

 

 

 

E41

Final stage reports error.

Check motor and cable for ground fault, short circuit

Quit

yes

 

 

COMPAX 35XXM: Short circuit of the

fault and function; remove extreme external sources

 

 

 

 

ballast resistance or undervoltage

of fault.

 

 

 

 

 

24V

 

 

 

 

 

 

 

COMPAX 1000SL:

 

 

 

 

 

 

 

Overvoltage or ballast switching

 

 

 

 

 

 

E42

Resolver / sensor error.

Check resolver cable and connector for correct

Quit

yes

 

 

 

connections and faults.

 

 

 

 

 

A special error code can be found in channel 67 of

 

 

 

 

 

the optimization display. This means

 

 

 

 

 

Error No. 1 ... 30: Sensor indicates error

 

 

 

 

 

Error No. > 30:

COMPAX indicates error

 

 

 

 

 

Error No. =160:

Sensor level too high

 

 

 

 

 

Error No. =161: Sensor level too low

 

 

 

 

 

(implement level adaptation using parameter P131)

 

 

 

E43

Output overloaded.

Check I/O cables, connectors and external circuits.

Quit

yes

 

 

 

Note load limits (refer to start-up manual).

 

 

 

E44

Positive auxiliary voltage outside

Switch unit on again.

Power on

yes

 

 

tolerances.

 

 

 

 

 

 

E45

Negative auxiliary voltage outside

Switch unit on again.

Power on

yes

 

 

tolerances.

 

 

 

 

 

 

E46

Supply voltage +24V is too high.

Check +24V DC power unit.

Power on

yes

 

E47

Supply voltage +24V is too low.

Check +24V DC power unit.

Power on

yes

 

224

Please note: the operating instructions (pages 67 - 171) as well as the application examples (pages 225 - 237) can be found in the complete product manual which is available as PDF file on CD

Page 224
Image 224
Parker  Products COMPAX-M /-S (L) manual 224, Too hard E40