Overview:

Overview of unit technology

7.1.2 Overview of unit technology

COMPAX-M and COMPAX-S

!work with the same firmware,

yet have differences with regard to

!housing and assembly technology and

!power areas.

The following table shows the main features of the range of available units

Unit

hardware

 

 

Connector

assignment / cable

Technical data

 

Common function characteristics:

COMPAX P1XXM COMPAX 02XXM COMPAX 05XXM COMPAX 15XXM

Interfaces:16 (8 with COMPAX 1000SL) digital inputs/outputs, RS232; machine zero, limit switch, override input

Fieldbus options: RS485, Interbus-S, Profibus, CS31, CAN – Bus, CANopen, HEDA (synchronous serial realtime interfaces)

Other options (excluding COMPAX 1000SL): absolute encoder sensor; encoder input; encoder simulation; D/A monitor

Supply via central mains module: NMD10 / NMD20: Up to max. 3*500V AC

Dimensions (DxHxW):

COMPAX P1XXM:

COMPAX-M:

 

340*400*60 [mm]

340*400*85 [mm]

Design:

 

Power:

COMPAX-M with NMD

 

COMPAX ...

mains module

Power Supply COMPAX-MCOMPAX-M

P1XXM: 3.8 kVA

Installation: in series

 

02XXM: 4.5 kVA

 

05XXM: 8.0 kVA

 

 

15XXM: 17 kVA

Configuration

 

 

 

Positioning and

control functions

 

 

Optimization

functions

 

 

Interfaces

 

 

 

/

 

COMPAX 35XXM

Supply Up to max. 3 * 500V AC (integrated power unit)

 

Dimensions (DxHxW):

40 * 400 * 220 [mm]

 

Design:

Power

 

 

35.0 kVA

COMPAX-M

Automation

15

Accessories options

 

Status

 

Parameter

 

Error list

Page 15
Image 15
Parker  Products COMPAX-M /-S (L) Overview of unit technology, Common function characteristics, Compax P1XXM COMPAX-M