Configuration

Front plate operation (not available with COMPAX 1000SL)

8.2Configuration

8.2.1 Front plate operation (not available with COMPAX 1000SL)

Unit

hardware

 

 

Connector

assignment / cable

Querying status values and modifying the bus parameters.

Meaning of the bus parameters:

Acknowledging error messages

Using the COMPAX front plate, you can query particular status values and perform the most important bus settings. Also whenever an error occurs, COMPAX shows the error number on the display.

choice of operation

A modes B

 

 

Enter

Enter

 

 

 

call smaller

call higher

call smaller

call higher

 

 

Status

Status

C-parameter

C-parameter

choose

number

number

number

number

choose

 

 

 

 

Status

 

 

 

 

number of

number

 

 

 

 

C-parameter

 

 

Enter

 

Enter

 

 

without

without

decrease

increase

 

status

function

function

value

value

change

 

 

 

 

indicator

 

 

 

 

C-parameter

 

 

Enter

 

Enter

 

 

 

A

 

B

 

The following status values can be displayed via the front plate:

S03-S08, S11, S19-S26 (hexadecimal display), S27, S30, S31, S37-S39 (description of the status values: see Page 207).

The remaining status values can be queried via the interfaces.

C parameters

 

COMPAX parameters

Meaning

 

 

Valid from

C01

 

 

 

P194

 

Address of unit

 

Power on

C02

 

 

 

P195

 

Baud rate:

 

Power on

C03

 

 

 

P196

 

Bus protocol

 

Power on

C11

 

 

 

P250

 

HEDA address

 

immediately

C04 - C10

 

 

 

 

 

reserved

 

 

 

 

 

 

 

 

 

 

 

 

Display

Baud rate

Display

Baud rate

 

Display

 

Baud rate [Baud]

value

 

[Baud]

value

[Baud]

 

value

 

 

0

 

600

31

31 250

 

172

 

172 800

1

 

1200

38

38 400

 

187

 

187 500

2

 

2400

50

50 000

 

250

 

250 000

4

 

4800

57

57 600

 

345

 

345 600

9

 

9600

62

62 500

 

375

 

375 000

10

 

10 000

76

76 800

 

500

 

500 000

19

 

19 200

100

100 000

 

800

 

800 000

20

 

20 000

115

115 200

 

999

 

1 000 000

28

 

28 800

125

125 000

 

 

 

 

 

Please see operating instructions for the bus option used for the relevant range of values and the precise setting options.

Once you have rectified the cause of the error, you can acknowledge the error by pressing the "Enter" key.