COMPAX parameter

 

No.

Meaning

Unit

Minimum

Default

Maximum

Valid

 

 

 

 

 

value

value

value

from...

 

P184

Selection parameters for HEDA – process value

40: encoder position

 

 

VP

 

(master)

42: internal time base

 

 

 

 

Default value: P184=0

43: scaled master position

 

 

 

 

44: nominal pos. value in resolver increm.

 

 

 

 

45: actual pos. value in resolver increments

 

 

 

 

46: differentiated resolver position

 

P185 – P187

HEDA – parameter

 

 

 

 

 

 

 

 

P188

Selection

parameters for HEDA – process value

40:

encoder coupling for encoder input

VP

 

(slave)

 

signals (P184=40)

 

 

Default value: P188=0

140: encoder coupling for other input

 

 

 

 

 

signals (P184

40)

 

 

 

 

 

42:

internal time base

 

 

 

 

43:

scaled master position

 

P191 – P196

Bus – parameter

 

 

 

 

 

 

 

 

P197

Order (status S33)

 

 

"Read only" – parameter

 

P198

Part (status S34)

 

 

"Read only" – parameter

 

P202

With machine zero mode P212="8": Distance

motor

3

 

0

 

255

VP

 

machine zero – limit switch (setting "0"

revol.

 

 

 

 

 

 

 

corresponds to "3")

 

 

 

 

 

 

 

 

P206

Enables the absolute value sensor input / the

="1": absolute value sensor input enabled or

VP

 

reset function of option S2 / absolute value

 

reset function switched on (S2 opt.)

 

 

sensor

= "2": absolute value sensor enabled

 

P211

Disable and modify the Teach In – function

"0"

The teach data record and teach real

immedia-

 

 

 

 

zero functions are enabled.

tely

 

Also:

"1"

Teach in real zero is blocked, data

 

 

enable final stage with OUTPUT O0="0" without

 

record indicator is set to 1 using I1 + I4 .

 

 

"2"

Teach in set is blocked, data record

 

 

lag (Bit 2="1")

 

indicator is set to 1 using I1 + I5 .

 

 

 

 

 

 

 

 

 

 

(Teach real zero is enabled)

 

 

 

 

"3"

The teach data record and teach in real

 

 

 

 

 

zero functions are blocked. With I1 + I4,

 

 

 

 

 

Teach N or I1 + I5, the data record

 

 

 

 

 

indicator is set to 1.

 

 

 

 

"4...7": The final stage is enabled with

 

 

 

 

 

OUTPUT O0="0" without lag (P. 123)

 

P212

Machine – zero – mode

"0":

MZ equals external initiator & resolver

immedia-

 

 

 

 

zero / 2 reversing initiators.

tely

 

 

 

"1": MZ equals external initiator & resolver

 

 

Settings "3" and "4" with COMPAX XX00 and

 

zero.

 

 

 

 

 

 

"3":

MZ equals external zero pulse

 

 

COMPAX XX30 only

"4":

MZ equals external initiator & external

 

 

 

 

 

zero pulse.

 

 

 

 

 

 

 

 

"5": MZ equals resolver zero

 

 

 

 

"6":

reserved

 

 

 

 

 

 

 

 

"7": MZ equals external initiator (without

 

 

 

 

 

resolver zero).

 

 

 

 

 

 

"8": MZ equals limit switch

 

 

 

 

"10": teaches machine zero

 

 

 

 

"11": MZ equals initiator (without resolver

 

 

 

 

 

zero) / 2 reversing initiators.

 

P213

Machine zero direction

"0": to the right

"1": to the left

VP

P214

Encoder direction

"0": positive direction when encoder is

VP

 

 

 

 

turning clockwise.

 

 

 

 

"1": positive direction when encoder is

 

 

 

 

 

turning anti-clockwise.

 

P215

Direction of rotation

"0": motor to the right

"1": motor to the left

VP

Unit

hardware

 

 

Connector

assignment / cable

Technical data

 

 

 

Configuration

 

 

 

Positioning and

control functions

 

 

Optimization

functions

 

 

Interfaces

 

 

 

Accessories /

options

 

 

Status

 

 

 

Parameter

 

 

 

219

Error List:

Page 219
Image 219
Parker  Products COMPAX-M /-S (L) P184 Selection parameters for Heda process value, Master, Default value P184=0, Also