Interfaces

Using the parameters P76 and P77, you can select 2 parameters and adapt them to the required measuring range.

Unit hardware

/ cable

Assignment of the channels

Meaning and range of values of P76 / P77

Channel 2: X11/4;

X17/1 for COMPAX 1000SL6

 

Channel 3: X11/5;

X17/2 for COMPAX 1000SL

 

 

 

 

 

No.

 

Parameter

Range

P76

 

Measuring parameter of channel 2.

0...18

Value before decimal p.

(see below for meaning).

 

P76

 

Gain factor from channel 2.

0.1... 10 000 000

Value after decimal point7

(factor = value * 10 000 000)

 

P77

 

Measuring parameter of channel 3.

0...18

Value before decimal p.

(see below for meaning).

 

P77

 

Gain factor from channel 3.

0.1... 10 000 000

Value after decimal point

(factor = value * 10 000 000)

 

The parameters can only be actuated once you have entered the password. They are validated using VP.

Connector

assignment

Technical data

 

Configuration

 

D/A monitor

Service D/A monitor:

Selection of measuring parameter using P76 / P77

standard

D/A monitor (option D1): Selection of measuring parameter using P73 / P74

measuring

Measuring

Measuring parameter

 

 

8

parameter No.

 

Reference value

parameters

0

Nominal speed value sensor

 

20 000 min-1

 

 

 

1

Tracking error

 

128›Motor revolutions

 

2

Advance speed control

 

20 000 min-1

 

3

Nominal speed value of position controller

20 000 min-1

 

4

Actual speed value

 

20 000 min-1

 

5

Speed deviation

 

20 000 min-1

 

6

Not assigned

 

 

 

 

7

Not assigned

 

 

 

 

8

Nom. value of transverse current (torque)9

200A

 

9

Intermediate circuit voltage

 

1000V

 

10

Sine for co-ordinate transformation

 

 

 

 

11

Voltage positioning signal for phase U

2 * ULS

 

12

Voltage positioning signal for phase V

 

2 * ULS

 

13

Phase current for phase U

 

200A

 

14

Phase current for phase V

 

200A

 

15

Actual value of transverse current (torque)10

200A

 

16

Longitudinal current

 

200A

 

17

Scaled transverse voltage

ULS )

2 *

ULS

 

 

(For amplification of 1 use: 10V = 2 *

 

 

 

18

Scaled longitudinal voltage

ULS )

2 *

ULS

 

 

(For amplification of 1 use: 10V = 2 *

 

 

You will find additional measuring parameters on Page 210!

6The initiator signals are looped through the monitor box ASS1/01. 7 .0000001=factor 1

.000001=factor 10

.999999=factor 10 000 000

8Physical value with 10V output voltage and an amplification of 1

9To determine torque:

torque = transverse current * 0.71 * total torque constant

10To determine torque:

torque = transverse current * 0.71 * total torque constant

57

 

 

 

 

Positioning and

control functions

 

 

Optimization

functions

 

 

Interfaces

 

 

 

Accessories /

options

 

 

Status

 

 

 

Parameter

 

 

 

Error list

 

 

 

Page 57
Image 57
Parker  Products COMPAX-M /-S (L) manual Interfaces, Monitor, Standard, Measuring, Parameters