Parker Products COMPAX-M /-S (L) manual Control processes for optimization, Accel

Models: COMPAX-M /-S (L)

1 242
Download 242 pages 31.85 Kb
Page 131
Image 131

Optimization functions

Optimization parameters

Control processes for optimization

Targets / problems

 

Stiff-

Damp-

Advance contr.

Acceleration

Ramp

Other

 

 

ness

ing (P24)

factors (P25,

time

shape

measures

 

 

(P23)

 

P26, P70)

(ACCEL)

(P94)

 

Minimizing lag error

 

increase

-

=100%

increase

-

-

 

 

 

 

optimize if

 

 

 

 

 

 

 

necessary

 

 

 

No harmonies

 

-

increase

decrease

increase

quadratic

increase max.

 

 

 

 

 

 

(P94="3")

torque (P16)

Unusually high

 

decrease

decrease

decrease

increase

linear

increase max.

harmonies caused

 

 

 

 

 

(P94="1")

torque (P16)

by power limitation

 

 

 

 

 

 

 

Vibrating at higher

 

decrease

decrease

-

-

-

check min. mass

frequencies

 

 

 

 

 

 

(P92) and min.

(perceptible as noise)

 

 

 

 

 

 

moment of inertia

 

 

 

 

 

 

 

(P81).

Vibrating at lower

 

-

increase

-

-

-

check max. mass

frequencies

 

 

 

 

 

 

(P88) and max.

(perceptible as

 

 

 

 

 

 

moment of inertia

motion)

 

 

 

 

 

 

(P82).

High motor or final

 

decrease

-

-

increase

linear

decrease max.

stage temperatures

 

 

 

 

 

(P94="1")

torque (P16)

131