Operating Instructions

COMPAX-M / -S

PLC data interface (function not available with COMPAX 1000SL)

Modify parameters P1...P49

Acceptance of VP parameter

Status query

S1...S12 (actual values)

Status response S1...S12 (actual values)

Start sign

"E"

"1110"

Function code 1:

"1"

"0001"

Function code 2:

"3"

"0011"

Parameter No. tens column

Parameter No. digits column

Assignment code: "A"

"1010"

Sign

"0"

"0000": positive

 

"D"

"1101": negative

Numerical value 106

 

Numerical value 105

 

Numerical value 104

 

Numerical value 103

 

Numerical value 102

 

Numerical value 101

 

Numerical value 100

 

Decimal point

"C"

"1100"

Numerical value 10-1

 

Numerical value 10-2

 

End sign

"F"

"1111"

 

 

 

Start sign

"E"

"1110"

Function code 1:

"1"

"0001"

Function code 2:

"4"

"0100"

End sign

"F"

"1111"

 

 

 

Start sign

"E"

"1110"

Function code 1:

"1"

"0001"

Function code 2:

"6"

"0110"

Numerical value 101

 

Numerical value 100

 

End sign

"F"

"1111"

 

 

 

Start sign

"E"

"1110"

Sign

"0"

"0000": positive

 

"D"

"1101": negative

Numerical value 106

 

Numerical value 105

 

Numerical value 104

 

Numerical value 103

 

Numerical value 102

 

Numerical value 101

 

Numerical value 100

 

Decimal point

"C"

"1100"

Numerical value 10-1

 

Numerical value 10-2

 

Numerical value 10-3

 

End sign

"F"

"1111"

The following signs are not necessary when transferring:

Positive prefixes and initial zeros.

For whole number values: the decimal point and the figures after the decimal point.

158

Page 158
Image 158
Parker  Products COMPAX-M /-S (L) manual Operating Instructions