Chapter 3 Test Program for Field

Satellite T130, Satellite Pro T130, and PORTEGE T130 Maintenance Manual (960-Q08)

3.15 Error Codes and Error Status Names

The following table lists the error codes and error status names for the Diagnostic Tests.

Device Name Error Code Error Status Name
(Common) FF Data Compare Error
Memory 02 Protected Mode Not Changed
?? Other Error
FDD 01 Bad Command Error
02 Address Mark Not Found
03 Write Protected
04 Record Not Found
06 Media Change Line Error
08 DMA Overrun Error
09 DMA Boundary Error
0C Select Media Error
10 CRC Error
20 FDC Error
40 Seek Error
80 Time Out Error
?? Other Error
HDD 01 Bad Command Error
02 Bad Address Mark Error
04 Record Not Found
05 HDC Not Reset Error
07 Drive Not Initialized
09 DMA Boundary Error
0A Bad Sector
0B Bad Track Error
10 ECC Error
11 ECC Recover Enabled
20 HDC Error
40 Seek Error
80 Time Out Error
AA Drive Not Ready

Table 3-15-1 Error codes and error status names (1/2)