Chapter 3 Test Program for Field

3.4System Test

To execute the System Test select 01 from the Diagnostic Test Menu, press Enter and follow the directions on the screen. The System Test contains three subtests. Move the highlight bar to the subtest you want to execute and press Enter.

Subtest 01

FAN ON/OFF Checking

 

 

Select 1,2,3 to control FAN on/off , 1=Fan on , 2=Fan off , 3=Exit .

 

[BOIFAN2.EXE] Program Version: 1.0

 

1: Fan On 2: Fan Off 3: Exit

 

 

Fan1 Status on Fan1RPM: 5000 or

Fan1 Status OFF Fan1RPM: 0

 

Fan2 Status on Fan2RPM: 2500 or

Fan2 Status OFF Fan2RPM: 0

Subtest 02

Battery Test

 

This will display battery information for check, press [ESC] to exit.

[BOIPCU.EXE] Program Version : 1.0 03-27-2007

 

voltage

: 12522 mV

Remaining capacity alarm

: 400 mAh

temperature

: 24.4 ‘C

Remaining time alarm

: 10 min

current

: 1330 mA

Battery mode

: 0

average current

: 1327 mA

AtRate

: 0 mA

relative state of charge

: 93 %

At rate time to full

: 65535 min

absolute state of charge

: 89 %

At rate time to empty

: 65535 min

remaining capacity

: 3546 mAh

At rate O. K.

: FFFF

full charge capacity

: 3800 mAh

Maximun error

: 2 %

run time to empty

: -1 min.

Charging current

: 2800 mA

average time to empty

: -1 min.

Charging voltage

: 12600 mA

average time to full

: 101 min.

Manufacturer name

: SANYO

cycle count

: 10 times

Device name

: NS2P3SZDNVWR

design capacity

: 4000 mAh

Device chemistry

: LION

design voltage

: 11100 mV

Manufacturer data

: 0

specification information : 2.1

Manufacture date

: 9/13/2005

serial no.

: 32009

 

 

STATUS

: INIT

 

 

Press [ESC] KEY to exit

Satellite T130, Satellite Pro T130, and PORTEGE T130 Maintenance Manual (960-Q08)

Page 83
Image 83
Toshiba PROT130 manual System Test, Ffff