Parker Products COMPAX-M /-S (L) 8 RS232 interface, Absolute value sensor option A1 Interfaces

Models: COMPAX-M /-S (L)

1 242
Download 242 pages 31.85 Kb
Page 59
Image 59

7.9.8 RS232 interface

Wiring diagram SSK1/...:COMPAX - PC/terminal

X6

 

 

PC / terminal

 

 

9-way Sub-D-pin

 

 

 

 

 

 

 

 

 

 

 

 

plug shell with screwed

1

 

 

 

6

 

1 connection UNC4-40

 

 

6

9

 

5

5

 

 

9

 

 

 

 

 

 

 

9pol. Sub-D-socket board

 

 

 

 

n.c.

1

 

 

 

 

 

RxD

2

 

2

RxD

TxD

3

 

3

TxD

DTR

4

 

4

DTR

DSR

6

 

6

DSR

GND

5

 

5

GND

RTS

7

 

7

RTS

CTS

8

 

8

CTS

+5V

9

 

 

 

 

 

housing

 

housing

 

2

 

 

 

 

 

 

7 x 0.25mm + shield

 

 

 

 

Apply screen on both sides to surface.

7.9.9 Absolute value sensor (option A1)

Interfaces

Unit

hardware

 

 

Connector

assignment / cable

Technical data

 

 

 

Configuration

 

 

 

Positioning and

control functions

 

 

Optimization

functions

Cable plan GBK1/..: COMPAX absolute value sensor

The option A1 cannot be used for COMPAX 1000SL.

X16

absolute enoder

 

 

 

 

 

 

8

9

 

 

plug :

1

6

 

9-way Sub-D-pin

12

10

1 plug housing with

7

2

 

 

screwed connection

 

 

 

 

9

5

UNC4-40

 

 

 

 

 

 

 

6

3

 

 

 

 

 

plug :

 

 

 

 

 

 

 

5 11 4

 

 

 

C12FUR

 

T+

6

 

 

3

T-

1

 

 

11

D+

8

 

 

2

D-

3

 

 

10

+24V 9

 

 

8

GND 5

 

 

1

housing

4 x ( 2 x 0.25mm2 ) + shield

 

 

housing

n.c.

2

 

 

 

 

n.c.

4

 

 

 

 

 

 

n.c.

7

 

 

 

 

 

 