Configuration via PC using "ServoManager"

Installing ServoManager

8.3Configuration via PC using "ServoManager"

There is a separate manual describing how to work with ServoManager.

8.3.1 Installing ServoManager

Preparation Before installation, deactivate the following programs:

any virus detection software.

the Miro Pinboard in Miro graphic cards. Information concerning these programs.

Following installation, the virus software can be reactivated.

Problems may also occur during program execution with Miro Pinboard.

Installation Start the "Setup.exe" program on disk 1. The installation is a menu-guided process. Following the installation, a Windows program group will appear containing the ServoManager and the terminal.

8.3.2Configuring COMPAX

Create connection to COMPAX: cable SSK1 (see Page 59).

Call up ServoManager.

Create a new project (Menu: Project: New).

Using the menu "Axis: Insert: From controller" to set up an axis which contains all COMPAX settings (all parameters: including system parameters and data records, curves are also available for COMPAX XX70).

Use the menu "Servo-Tools: to switch to ParameterEditor.

Call up menu "Configuration: Guided configuration".

All configuration parameters are queried one after another.

8.3.3Individual configuration of synchronous motors

In addition to the motors contained in ServoManager / ParameterEditor, you can configure almost all synchronous motors. The conditions required for the motors and resolvers are listed in the start-up manual under "Technical data".

To modify motor parameters, the motor must be switched off (use OUTPUT O0=1 or press the "-" button on the front plate while switching on COMPAX).

You will find the data required for this on the HAUSER motor type plate.

91

Unit

hardware

 

 

Connector

assignment / cable

Technical data

 

 

 

Configuration

 

 

 

Positioning and

control functions

 

 

Optimization

functions

 

 

Interfaces

 

 

 

Accessories /

options

 

 

Status

 

 

 

Parameter

 

 

 

Error list

 

 

 

Page 91
Image 91
Parker  Products COMPAX-M /-S (L) Configuration via PC using ServoManager, Installing ServoManager, Configuring Compax