Start-up manual

COMPAX-M / S

7.7COMPAX 1000SL Unit characteristics

7.7.1 Connector and terminal assignment for COMPAX 1000SL

 

H1

H2

 

 

X6

X17

 

X6 RS232

RS232

Limit Switch

24 V DC

 

 

 

X17

 

 

 

initiators

X5

X7

 

bus

Fieldbus In

Fieldbus Out

 

systems:

R Dump

X5 IN

 

 

 

X7 OUT

X13

X12

 

 

 

X13

 

 

 

encoder

Encoder

Resolver

 

X12

 

 

 

 

resolver

 

 

 

X19 in-/

X19

 

 

 

 

 

output

COMPAX - SL

 

 

 

Input / Output

 

 

 

 

 

 

 

 

 

 

 

 

X3 24V DC

 

 

 

 

 

 

 

 

 

 

 

supply

 

 

 

 

X3

 

X15

 

 

 

 

Input + -

 

HEDA In

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X14/X15

(Option)

 

 

 

 

 

 

 

 

 

 

 

HEDA

 

 

 

 

 

 

 

 

 

 

X14

 

 

 

 

X4

 

Out

 

 

 

 

 

 

 

 

 

 

 

 

PE

 

HEDA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-

 

 

 

 

 

 

 

 

 

+

 

 

 

 

X4 ballast

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X1

Brake

 

resistance

 

 

 

 

 

 

 

 

 

 

 

 

 

+ -

 

X1 motor /

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PE

 

 

motor brake

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V W

Motor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

U

X2

 

PE

AC

 

 

 

 

N

V

 

 

L1

230

X2 230V AC

 

 

 

 

 

 

 

supply

 

 

 

 

 

 

PE -

 

 

 

connection

Before wiring up, always de-energize the unit.

Even once the mains supply has been switched off, dangerous levels of voltage can remain in the system for up to 5 min.

When working with motors without a holding brake, the brake lines must not be connected to COMPAX

Caution!

If the unit has no control voltage, displays will not indicate if operating voltage is present.

PE – terminal:

at least 2.5mm2

 

 

LED display

The following statuses are shown by the LEDs.

 

 

Status

Red LED (H2)

Green LED (H1)

 

24V not available

off

off

 

24V are switched on, boot up

on

off

 

Unit OFF

off

blinking

 

Unit error; drive switched off

on

blinking

 

Unit error; drive powered

on

on

 

Unit RUNNING

off

on

40