Absolute value function with standard resolver

8.2.6 Absolute value function with standard resolver

 

Absolute value function without special sensor for up to 4096 rpm

 

Activated with

Parameter P206=2 is used to activate the absolute value resolver.

 

 

P206=2

COMPAX reads the current actual position cyclically every 2ms and stores this

 

 

data alternatively onto 2 memory stores (Pos 2, Pos 3) protected against power

 

 

failure.

 

 

 

 

The current imported position is shown in Status S12.

 

 

 

 

After Power On, the last stored actual positions (Pos 2 and Pos 3) are read and

 

 

compared with each other and the current read resolver angle (Pos 1).

 

 

A3 is set, when

 

 

 

 

the last saved actual position (Pos

P

Pos 1

 

 

2) lies within a definable window

 

 

 

 

1

 

 

 

 

6

 

 

 

 

1

 

 

 

 

(P161) around Pos 1,

 

P

Pos 2

 

 

 

1

 

and when

 

6

Pos 3

 

 

1

 

 

 

 

Pos 2 and Pos 3 are less than

P161 from one another (to ensure that the drive stops when switched off).

Renewed referencing (find machine zero) is not required.

S12 is copied after Power On, enabling of the controller or after an error in S1.

If the last saved actual position (Pos 4) lies outside a definable window (P161), then A3 is not set, so a renewed referencing (find machine zero) is necessary.

Condition: in the switched off status, the motor or mechanics must not be moved. Ensure this by using e.g. a motor brake or self-braking gearbox.

Maximum angle P161 gives the maximum permissible angle difference between the saved and the difference P161: current actual position when switching on.

Range: 1 ... 2047; default value 100; where 4096 = 1 motor revolution.

If P161 is exceeded, then a new reference is necessary (find machine zero).

Note After error E42 (resolver/sensor error), referencing must always be implemented.

The absolute value sensor function described above only functions with resolvers.

The absolute value function with resolvers is not supported by COMPAX XX30.

Value range S12 The value range of the absolute value S12 lies between –2048 and 2047.9999 (0 corresponds to the machine zero when P1=0). In addition, a value sign conversion occurs (value jumps from the positive maximum value to the negative maximum value; or vice versa), whereby at the next comparison S12S1 an error of precisely 4096 occurs.

Use a real zero P1 to shift the value range (around –P1). Ex. 1: P1=-2000 value range S12: -48 ... 4047 rpm.

With knowledge of this relationship, it is possible to create a positive travel area of maximum 0 ... 4096 by the following actions:

!Travel to center of total travel area

!PH with P1=-2048 and P212=10

!S1 = S12 = 2048 at this point

Travel from POSA 0 ... POSA 4095.9999 possible without value sign conversion.

79

Unit

hardware

 

 

Connector

assignment / cable

Technical data

 

 

 

Configuration

 

 

 

Positioning and

control functions

 

 

Optimization

functions

 

 

Interfaces

 

 

 

Accessories /

options

 

 

Status

 

 

 

Parameter

 

 

 

Error list

 

 

 

Page 79
Image 79
Parker  Products COMPAX-M /-S (L) manual Absolute value function with standard resolver, Activated with, P206=2