Optimization functions

 

 

 

 

External position localization with position adjustment

 

 

 

 

 

 

 

Para-

Meaning

 

valid

 

 

meter

 

 

 

 

from..

 

 

P214

Encoder direction.

 

VP

 

 

 

="0": positive direction for encoder rotating clockwise.

 

 

 

 

="1": positive direction for encoder rotating anti-clockwise.

 

 

 

 

Setting aid:

 

 

 

 

 

Switch off external position adjustment (P144=4) and data record

 

 

 

 

 

 

P214=0.

 

 

 

 

 

Note S42 (position of external sensor).

 

 

 

 

Proceed with POSR x axis.

 

 

 

 

 

S1 and S42 must change by the same value (x).

 

 

 

 

 

If the prefix of the modification is different, set data record P214="1".

 

 

 

 

 

If the modification has a different amount, check P143 and P98.

 

 

 

 

The command "SPEED SYNC" cannot be used in external position

 

 

localization!

 

 

 

Limit values of

A number overrun is possible in special applications. To prevent this occurring, the

parameters

following condition must be met: V

1

 

 

Determine V depending on drive type and measuring unit:

Unit

hardware

 

 

Connector

assignment / cable

Technical data

 

 

 

Configuration

 

 

Drive type

Measuring unit

Determining V

 

 

Spindle drive

mm (inch)

V =

K

P85(25.4)

 

 

 

 

 

 

 

 

 

Rack-and-pinion/

mm (inch)

V =

K

P85(25.4)

 

 

toothed belt

 

 

 

 

 

 

P82

 

 

 

 

 

 

 

 

General drive

mm (inch)

V =

K

1000(25.4)

 

 

 

 

 

 

 

 

 

General drive

Incr.

V =

K

 

 

Using

K = P98 16384 . P83 P143

Positioning and control functions

Slip filter for external position localization

A slip filter with a differentiating element (D-element) is provided to optimize external position adjustment.

No.

Meaning

Unit

Minimum

Default

Maximum

Valid

 

 

 

value

value

value

from...

P67

D-element slip filter

%

0

100

500

VP

P68

Slip filter lag

%

0

100

5000

VP

Both parameters are set to 100% as standard. The time constants are then identical and the filter ineffective. Meaning:

Parameter

Effect

Application

P67

= P68

Filter ineffective (standard)

P67

< P68 or

Filter has

Low resolution of measuring system

P67

= 0

delaying effect

Interference on the measuring signal

P67

> P68

Filter has

at high dynamic requirements.

 

 

differentiating

Conditions: high-resolution measuring

 

 

effect

 

 

system and low interference on the measuring

 

 

 

signal.

Optimization

functions

 

 

Interfaces

 

 

 

Accessories /

options

 

 

Status

 

 

 

Parameter

 

 

 

list

 

137

Error

Page 137
Image 137
Parker  Products COMPAX-M /-S (L) manual Slip filter for external position localization, Limit values, P214