Parker Products COMPAX-M /-S (L) manual Mains module NMD10/NMD20, Overview NMD

Models: COMPAX-M /-S (L)

1 242
Download 242 pages 31.85 Kb
Page 22
Image 22

Start-up manual

COMPAX-M / -S

7.3Mains module NMD10/NMD20

The mains module ensures the supply of current to the COMPAX-M (not COMPAX 35XXM) axis controller and the SV drive connected into the network. It is connected to the 3-phase power supply with 3 * 400V AC and PE. 24V DC voltage must be provided for the control electronics.

7.3.1 Overview NMD

Power Supply

L1

L2 L3 PE

24V

 

PE

+ -

X1

 

 

 

 

PE

 

 

 

PE

 

 

 

X2

 

 

 

 

+LS

 

 

 

+LS

-LS

 

 

 

-LS

+

 

+

24V

 

24V

X3

 

 

-

 

-

X4

 

 

 

 

 

 

 

 

 

voltage supply 3*(80-500)V AC/

X1 24V CC

X2 power inter- mediate loop

X3 control voltage 24 V

X4 control- and status-signals Bus signals continuation

X6 bus- systems IN

 

Ready Error

 

 

X6

X7

X7

bus-systems

 

 

IN

RS 485OUT

 

OUT

 

X8

X8

Control

 

 

Control

X18 fan

Before wiring up, always de-energize the unit.

Even once the mains supply has been switched off, dangerous levels of voltage can remain in the system for up to 5 min.

The PE connection must be a 10mm2 version

7.3.2 Dimensions / installation

Dimensions and installation of the NMD10 and NMD20 power units correspond to the data for COMPAX-M (see Page 20).

22

Page 22
Image 22
Parker  Products COMPAX-M /-S (L) manual Mains module NMD10/NMD20, Overview NMD, Dimensions / installation