Start-up manual

 

COMPAX-M / -S

Technical data / Connections of inputs and outputs

 

 

 

 

 

7.9.3 Technical data / Connections of inputs and outputs

Detection of input

0 1 over 9.15V means that "1" is recognised

signals:

1 0 over 8.05V means that "0" is recognised

 

Load on outputs

 

 

 

 

1.

O1...O16

Total of max. 1.6A

 

(not applicable for

2.

O1...O4, O5...O8,

Per group of 4, max. 0.8A; taking due account of 1.

 

COMPAX 1000SL):

 

O9...O12, O13...O16

 

 

 

3.

O

per output, max. 0.3A and 40nF capacitive4; taking

 

 

 

 

into account 1. and 2.

 

Load on outputs for

Per output, max. 0.3A In total a sum load for all 8 outputs of max. 0.48A and

COMPAX 1000SL:

40nF capacitive5;

 

 

If overload occurs, an error message appears (E43: can be acknowledged with

Power off/on); the corresponding group of four is switched off.

Input connection using I7 as an example

Output connection using O7 as an example

PLC

COMPAX

24V

F23

4.7K

0V

 

COMPAX

 

 

 

X11/7

 

 

 

24V

 

 

 

 

F23

 

 

X11/1

 

100K

X19/23

22K

X8/7

 

 

 

 

 

 

 

X19/.

22K

 

 

 

 

 

 

 

22K

10nF

12K

X11/2

 

 

 

0V

X19/14

(X19 applies for COMPAX 1000SL)

 

PLC

X19/23

X11/1

X11/7

X8/15

X19/.

X19/14

 

X11/2

(X19 applies for COMPAX 1000SL)

 

Input/output connection for 2 COMPAXs

For reasons of interference protection, we would recommend that you use a screened cable for the digital inputs and outputs.

With COMPAX 1000SL, the screen is connected with the Sub-D housing. A protective connection is required when there is inductive load present.

24V

 

1st COMPAX

 

 

 

 

2nd COMPAX

 

 

X19/23

 

 

X19/23

 

 

 

24V

 

 

F23

X11/1

 

 

X11/1

 

F23

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

22K

100K

 

 

 

X8/15

 

 

X8/7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X19/.

 

 

 

X19/.

22K

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4.7K

 

 

22K

 

 

 

 

 

 

 

 

 

10nF

12K

 

 

 

X19/14

 

 

X19/14

 

 

 

0V

 

 

 

 

 

 

 

0V

 

 

 

X11/2

 

 

 

X11/2

 

 

 

 

(X19 applies for COMPAX 1000SL)

4A maximum of 4 COMPAX – inputs can be connected to one output.

5A maximum of 4 COMPAX – inputs can be connected to one output.

54

Page 54
Image 54
Parker  Products COMPAX-M /-S (L) manual Technical data / Connections of inputs and outputs, Compax 1000SL