Optimization functions

Optimization display

Unit hardware

You will find the meanings of the DA monitor values on Page 52.

Access to additional parameters via S13 and S14:

P233/P234

Meaning

15

Current number of HEDA transmission errors

16

Average no. of HEDA transmission errors per second

17

Total number of HEDA transmission errors since beginning of

 

synchronization

18

Process nominal value received via HEDA

19

HEDA control word

 

Bit 331: Transmission error COMPAX -> IPM

 

Bit 8: fast start via HEDA

20

HEDA status word

 

Bit 0="1": no errors (corresponds to COMPAX output O1)

 

Bit 1="1": no warnings (corresponds to COMPAX output O2)

 

Bit 3="1": transmission error IPM -> COMPAX

 

Bit 8="1": COMPAX lag warning (="1" - in position, i.e. within lag

 

 

warning window)

 

Bit 9="1": HEDA interface active (COMPAX synchronized)

 

Default setting: Bit 0="1", Bit 1="1", Bit 3="0", Bit 8="1", Bit 9="1":

 

S13/S14=771

21

CPX X50 max. pos. synchronous lag error [units corresp. P90]

22

CPX X50 max. neg. synchronous lag error [units corresp. P90]

23

Output value of D/A monitor channel 0 (10V corresponds to 1)

24

Output value of D/A monitor channel 1 (10V corresponds to 1)

25

Output value of service D/A monitor channel 2 (10V corresp. to 1)

26

Output value of service – D/A monitor channel 3 (10V corresp. to

 

1)

 

27

External encoder position (units corresp. P90)

28

Measuring error (Difference between resolver position and external

 

encoder position in the unit corresponding to P90)

29

Effective motor load in % of the permitted continuous motor load

 

(E53 is indicated from 100%)

30

Effective unit load in % of the permitted continuous unit load (E53

 

is indicated from 100%)

31

Mark synchronization function indicator (COMPAX XX70)

32

"Scaled correction factor" (COMPAX XX70)

33

"Cycle counter" (COMPAX XX70)

35

Digital inputs I1-I16

36

Status S16 (bits 16...23) and digital outputs O1-O16 (bits 0...15)

37

Encoder frequency channel 4 in incr./ms" (COMPAX XX60,

 

COMPAX XX7X)

39

Cause of calculation error E07

 

0

Invalid Operator

 

1

Division by 0

 

2

Overflow

 

3

Underflow

The corresponding number in the first column should be entered in the parameter. This means

P233 determines status S13 ! P234 determines status S14

You will find additional special diagnosis values on Page 210.

Connector

assignment / cable

Technical data

 

 

 

Configuration

 

 

 

Positioning and

control functions

 

 

Optimization

functions

 

 

Interfaces

 

 

 

Accessories /

options

 

 

Status

 

 

 

Parameter

 

31Bit counting begins with 0.

135

Error list

Page 135
Image 135
Parker  Products COMPAX-M /-S (L) manual Access to additional parameters via S13 and S14, P233/P234 Meaning