Parker Products COMPAX-M /-S (L) manual Compax standard parameters, P20 setting

Models: COMPAX-M /-S (L)

1 242
Download 242 pages 31.85 Kb
Page 214
Image 214

Appendix

 

 

 

 

 

COMPAX-M/S

COMPAX standard parameters

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No.

Meaning

 

Unit

Minimum

Default

Maximum

Valid

 

 

 

 

 

value

 

value

value

from...

 

P20

RS232 handshake

Software handshake

"0": without

 

 

 

Power on

 

 

 

 

"1": with XON, XOFF

 

 

 

 

 

Error transmission /

"0": Error only with interface activity and if

immediat.

 

 

P20 setting.

negative command

the transmitted command triggers an

 

 

 

acknowledgement

error.

 

 

 

 

 

 

The sum of the

 

 

 

 

 

 

(E90 - E94)

No neg. command acknowledgement

 

 

 

specified values is

 

(E90 - E94).

 

 

 

 

 

entered in P20.

 

 

 

 

 

 

 

"2": no transmission of error and no neg.

 

 

 

 

 

 

 

 

 

 

command acknowl. (E90 – E94).

 

 

 

 

 

"4": Messages are indated for errors and

 

 

 

 

 

neg. command acknowl. (E90 – E94)

 

 

 

 

 

as soon as th. occur w. Exx CR LF >.

 

 

 

 

 

"6": errors & neg. command acknow.

 

 

 

 

 

(E90 – E94) only with interface

 

 

 

 

 

activity.

 

 

 

 

 

 

 

End sign selection

"0": CR LF >

 

"8": CR

 

Power on

 

 

 

Binary transfer

"0": without

"16": with

 

immediat.

 

 

 

BCC: block check

"0": without

"128": with

 

Power on

 

 

 

EXOR via all signs apart

 

 

 

 

 

 

 

 

 

from the end sign

 

 

 

 

 

 

 

P21

Factor for influencing the travel per motor

 

0.1000

1.0000

10.0000

VP&VC

 

 

revolution

 

 

 

 

 

 

 

 

P22

Factor for modifying the speed which is

 

0.5000

1.0000

2.0000

VP&VC

 

 

allocated to speed SPEED 100%.52

 

 

 

 

 

 

 

P23

Stiffness of drive

 

%

10

 

100

5000

VP

 

P24

Speed controller damping

%

0

 

100

500

VP

 

P25

Speed – advance control value

%

053

 

100

500

VP

 

P26

Acceleration – advance control value

%

0

 

100

500

VP

 

P27

Moment of inertia

 

%

10

 

100

500

VP

 

P29

Machine zero comparison

Degre

0

 

0

360

VP

 

 

 

 

e

 

 

 

 

 

 

P35

Switch on mark reference

"0": switched off

"1": switched on

VP

 

P36

Limitation of speed correction value for external

% of

0

 

0

100

VP

 

 

position adjustment (only COMPAX XX00 and

nominal

 

 

 

 

 

 

 

speed

 

 

 

 

 

 

 

COMPAX XX30) ="0": switched off

(P104)

 

 

 

 

 

 

P37

Minimum travel to mark

corr.. P90

0.00

 

0.00

<P38

VP

 

P38

Maximum travel to mark

corr.. P90

>P37

 

0.00

4 000 000.00

VP

 

P39

Maximum feed length

corr..P90

P38

 

0.00

<P11 or P12

VP

 

P40

Control parameters

 

 

-4 000 000

0

+4 000 000

immediat.

 

P41

Control parameters

 

 

-4 000 000

0

+4 000 000

immediat.

 

P42

Control parameters

 

 

-4 000 000

0

+4 000 000

immediat.

 

P43

Control parameters

 

 

-4 000 000

0

+4 000 000

immediat.

 

P44

Control parameters

 

 

-4 000 000

0

+4 000 000

immediat.

 

P45

Control parameters

 

 

-4 000 000

0

+4 000 000

immediat.

 

P46

Control parameters

 

 

-4 000 000

0

+4 000 000

immediat.

 

P47

Control parameters

 

 

-4 000 000

0

+4 000 000

immediat.

 

P48

Control parameters

 

 

-4 000 000

0

+4 000 000

immediat.

 

P49

Control parameters

 

 

-4 000 000

0

+4 000 000

immediat.

 

52When motor nominal speeds have been modified, use this factor to perform a simple adaptation to the current program.

53When P93 = 4, P25 must be >0.

214

Page 214
Image 214