Status values of the standard unit (COMPAX

XX00)

Output of status bits via the front plate

The status bits are output via the front plate using 2 hex values.

S16, S17

S16:

Bit Meaning

1="1":No fault

="0":errors E1 ... E57; the drive does not accept any positioning commands. After "Power on", bit 1 remains at "0" until the self-test has been executed.

2="1":No warning ="0" Error E57

3Machine zero has been approached

4 Ready for start

5 Programmed nominal position reached

6 Idle after stop 7, 8 Bit 7 Bit 8

00 after OUTPUT O0 = "0"

10 after OUTPUT O0 = "1"

01 after OUTPUT O0 = "2"

S17:

Bit Meaning when "1"

1Password 302 active

2Service password active

3Command active; move commands (POSA, POSR; speed in speed control mode) are rejected using E92.

4Program memory running

5 Stop via input I6

6reserved

7RUN ("0" = OFF or switched off when error occurs)

8 ---

Bit sequence during transmission of S16 / S17:

Bit 1 is on the left (the transmission starts with bit 1)

E.g.: S17= "1000 0000" during ASCII transfer.

Bit 1

COMPAX front plate: display "01"

E.g.: password 302 active S17 = 0x80 (if all other bits ="0").

Explanation of error history S18

The errors which occur are recorded by COMPAX in an 8-stage shift register. The entire contents of this memory can be read using a status query. Once the error has been acknowledged, "99" is inserted. Once a new error occurs, this is inserted in the shift memory.

When querying using S18, the contents of the shift register are output separated by spaces.

Once the unit is switched off, S18 is retained. If the unit is switched off while an error is present, a Power On acknowledgement is created when the unit is switched on, i.e. a "98" is inserted in the shift memory.

Example: S18CRLF

Response: S018: 99 55 10 99 53 98 10 99CRLR>

The last error, an emergency stop (E55), has been acknowledged.

E10 occurred before this (E10 has not been acknowledged).

E53 has been acknowledged.

E10 has been acknowledged by Power on.

The error memory is completely reset to "00" by the reset parameter, i.e. "00" means no errors.

209

Unit

hardware

 

 

Connector

assignment / cable

Technical data

 

 

 

Configuration

 

 

 

Positioning and

control functions

 

 

Optimization

functions

 

 

Interfaces

 

 

 

Accessories /

options

 

 

Status

 

 

 

Parameter

 

 

 

Error list

 

 

 

Page 209
Image 209
Parker  Products COMPAX-M /-S (L) Output of status bits via the front plate, S16, S17, Explanation of error history S18