Start-up manual

COMPAX-M / -S

Service D/A monitor / override

 

 

 

7.9.5 Service D/A monitor / override

 

Assignment of X11 (not applicable for COMPAX 1000SL)

Connector: Phoenix MC1.5/7-ST-3.81

1 2 3 4 5 6 7

Pin

Assignment

 

 

1

+24V

 

 

2

Ground 24V

 

 

3

Override for speed reduction

 

 

4

Standard DA channel 2: 8 Bit, Ri=2.21k

;

 

5

Standard DA channel 3: 8 Bit, Ri=2.21k

;

 

6

Override; previous input for existing applications

 

7Screen

With COMPAX 1000SL, the override input is on X19/13 (see Page 53), the Service D/A monitors on X17/1 und X17/2 (see Page 55).

Override connection

Override - Connection for

COMPAX 1000SL

(not applicable for COMPAX 1000SL)

COMPAX

 

 

1K

 

 

+5V

 

 

X11/6

 

 

 

 

 

 

 

 

 

 

10K

 

 

100%

 

X11/3

10K

Override-

 

 

 

 

 

 

 

0% 10K

 

 

Signal

 

 

 

 

 

 

100nF

 

 

X11/2

GND

 

 

 

The override input is read in a cycle of 100 ms.

You can continue to use the previous override connection for current applications.

 

 

 

COMPAX 1000SL

 

 

 

+5V

1K

 

 

 

100%

10K

 

X19/13

 

Override-

 

 

0% 10K

 

 

Signal

 

 

 

 

 

 

100nF

 

 

X19/14

GND

 

 

 

The override input is read in a cycle of 100 ms.

Note:

Wiring of override with screened cables only

7.9.6 Service D/A monitor

The service D/A monitor gives you the option of outputting internal measurement and intermediate parameters from COMPAX in the form of analogue voltage in the range of ± 10V via X11 (X17 with COMPAX 1000SL) and visualizing these by means of an oscilloscope. This provides you with a capable aid for making the unit functions clear and qualifiable, especially during the start-up.

This function (which is available in all units) provides you with two analogue output channels with a resolution of 8 bit and these are updated every 100 µs.