Parker Products COMPAX-M /-S (L) manual Explanations for the block structure, Functions

Models: COMPAX-M /-S (L)

1 242
Download 242 pages 31.85 Kb
Page 69
Image 69

 

 

 

 

 

Overview:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Block structure of the basic unit (not applicable for COMPAX 1000SL)

 

 

 

 

 

Explanations for the block structure

 

 

 

 

 

Interfaces for data and status

 

 

PLC data interface

The following commands are available via 5 binary inputs (I7...I11) and 5 binary

 

 

 

 

 

outputs (O7...O11):

 

 

 

 

 

POSA, POSR, SPEED, ACCEL, GOTO, VP, modifying parameters P1..P49,

 

 

 

 

 

querying status S1...S12. (Function not available with the COMPAX 1000SL)

 

 

 

 

RS 232

 

 

 

 

 

All functions are available via RS232.

 

 

 

 

Bus systems

 

 

 

 

 

All functions are available via the bus interface (Interbus S, Profibus, CAN bus,

 

 

 

 

 

CANOpen, CS31 or RS485 (ASCII/binary with 2 or 4 wires). A description is

 

 

 

 

 

available as a separate item.

 

 

Binary inputs and

 

 

 

Inputs:

 

 

 

 

outputs

I1...I6: control functions or freely assignable.

 

 

 

 

 

I7...I16: freely assignable or programmable.

 

 

 

 

 

Outputs:

 

 

 

 

 

O1...O6: control outputs or freely assignable.

 

 

 

 

 

O7...O16: freely assignable or programmable.

 

Functions

 

 

 

 

 

 

 

 

 

Query status

The status can be queried via the PLC date interface, the bus interface and

 

 

 

 

 

partially via the front plate display.

 

Setting

 

 

 

 

 

 

parameters

 

 

 

 

 

 

Configuring

Operating mode, units for travel data, motor types, ramp shapes, directions, drive

 

 

 

 

 

types, reference systems, ....

 

 

 

 

 

 

 

 

 

 

Optimizing

Via the uncoupled stiffness, damping and advance control parameters.

 

 

 

General settings

 

 

 

 

Replacement and specification values,

 

 

 

 

 

limitations,

 

 

 

 

 

control parameters.

 

 

Programming data

 

 

 

Programming a sequential program with up to 250 data records.

 

 

 

 

records

 

 

 

 

 

 

 

 

 

 

 

 

Controlling

Functions: manual mode, start, stop, break, teach functions ....

 

 

 

 

 

Messages no fault, no warning, machine zero has been approached, ready for

 

 

 

 

 

start, position reached, idle after stop or break.

 

 

 

 

 

Program control: external data record selection, analyzing binary inputs, setting

 

 

 

 

 

binary outputs, triggering positioning processes,... .

 

System controller

Function monitoring and co-ordination

 

Control

 

 

Digital control with robust control loops. Automatic calculation from existing design

 

 

 

 

 

quantities.

69

Unit

hardware

 

 

Connector

assignment / cable

Technical data

 

 

 

Configuration

 

 

 

Positioning and

control functions

 

 

Optimization

functions

 

 

Interfaces

 

 

 

Accessories /

options

 

 

Status

 

 

 

Parameter

 

 

 

Error list

 

 

 

Page 69
Image 69
Parker  Products COMPAX-M /-S (L) Explanations for the block structure, Functions, Setting Parameters, System controller