Interfaces

 

 

 

 

Digital inputs and outputs

 

 

 

 

 

 

 

 

 

 

 

8.6.1.2 Free assignment of inputs and outputs

 

 

 

 

Free assignment

You can make the permanently assigned standard inputs I1 to I6 available for

of inputs

assignment using parameter P221. Meaning:

 

 

 

 

 

 

Input

Function without

Function with SHIFT

Valency

 

 

 

 

 

SHIFT

 

 

 

 

 

 

 

I1 (X8/1)

SHIFT

-

1

(Bit 1)33

 

 

 

I2 (X8/2)

Manual+

Find machine zero (MZ)

2

(Bit 2)

 

 

 

I3 (X8/3)

Hand–

Approach real zero (RZ)

4

(Bit 3)

 

 

 

I4 (X8/4)

Quit

Teach real zero

8

(Bit 4)

 

 

 

I5 (X8/5)

START

reserved

16

(Bit 5)

 

 

 

I6 (X8/6)

STOP

Break (breaks off data

32

(Bit 6)

 

 

 

 

record)

 

 

 

 

Unit

hardware

 

 

Connector

assignment / cable

Technical data

 

Setting P221

Example:

Free assignment of outputs

Each input is assigned a valency. Calculate the sum of the valencies of the required free inputs and enter this in parameter P221.

Hand+ and Hand- should be possible via the inputs; I1, I4, I5 and I6 should be freely available.

1 (I1) + 8 (I4) +16 (I5) +32 (I6) = 57

You will obtain this setting using P221 = 57.

Note that when I1 is freely assigned (SHIFT), you can no longer perform any "Functions with shift" via the inputs!

You can directly cancel all input functions (apart from Hand+ and Hand-) as commands using interfaces (RS232, bus system).

The status outputs O1 to O6 can be freely assigned using parameter P225.

Use P223 and P224 to assign the outputs of the OUTPUT WORD command of the bus systems (Interbus-S, Profibus, CAN – Bus, ...).

Use P245 and P246 to assign the outputs of the HEDA bus (COMPAX with IPM via the option A1).

Permanently assigned outputs of unit variants (COMPAX XX30, ...) cannot be masked.

Configuration

 

 

 

Positioning and

control functions

 

 

Optimization

functions

Interfaces

 

Structural diagram

O1 ... O6

O1 ... O6

P225

 

 

 

status outputs

 

0

 

 

 

Output x=y

 

1

P223 /

 

 

 

O1 ... O6

P224

 

 

RS232

 

O1 ... O16 0

 

 

1

O12 ... O16

 

 

command line

1

 

 

or

O7 ... O11

 

 

bussystems

 

 

 

 

 

 

P245 /

 

 

 

P18

 

 

PLC data interface

O7 ... O11

0

P246

 

= "1" or "3"

 

 

 

 

1

towards

 

 

 

 

 

 

 

 

 

outputs

 

Output WORD

O1 ... O16

 

 

 

 

bussystems

 

 

 

 

 

 

 

 

 

HEDA via IPM

O1 ... O16

 

 

 

 

 

 

 

 

33Counting starts at 1.

143

Accessories / options

 

Status

 

Parameter

 

Error list

 

Page 143
Image 143
Parker  Products COMPAX-M /-S (L) manual Free assignment of inputs and outputs, Inputs, Free assignment of outputs, Shift