Interfaces

Digital inputs and outputs

8.6.1.4 I/O assignment of variants

Unit hardware

 

cable

COMPAX XX30: Round table control

COMPAX XX50: Synchronous cycle control

COMPAX XX60: Electronic transmission

COMPAX XX70: Cam control

I12:

final stage enable

I13:

measuring error compensation by external position measurement

I14:

release brake

O14:

no measuring error

O16:

no power to final stage

 

 

I6:

STOP ineffective during synchronization process.

I1 & I6: BREAK interrupts the synchronization process.

I12:

Material simulation

I13:

Manual step

I14:

Switches on mark reference

I15:

Ends synchronous travel

 

(The "Fast start" function is not possible)

I16:

Mark input

O5:

Position reached at synchronization command (WAIT POSA, WAIT POSR)

 

="0"; when the axis starts

 

="1": after return run.

O14: Synchronous comparator

O15: Chaff length

O16: Reject length

 

 

I14:

Switches over the dimension reference

I15:

Transmission factor selection

I16:

Enable master nominal value

 

 

I12:

Enable final stage

I13:

="0": Decoupling ="1": Coupling

I14:

Mark input

I15:

="0": Disables auxiliary functions ; ="1": Enables auxiliary functions

I16:

Enables master position

O7...O14: Digital auxiliary functions.

O13/O14: Cannot be used via OUTPUT.

O14: Mark not in mark window.

O15: Lag warning

O16: Synchronous run

Connector

assignment /

Technical data

 

 

 

Configuration

 

 

 

Positioning and

control functions

 

 

Optimization

functions

 

 

Interfaces

 

 

 

Accessories /

options

Please refer to the instructions for the variant you are using for up-to-date information!

147

Status

 

Parameter

 

Error list

Page 147
Image 147
Parker  Products COMPAX-M /-S (L) manual 1.4 I/O assignment of variants, 147