Parker Products COMPAX-M /-S (L) manual Diagrams, Data record memory mode, Caption

Models: COMPAX-M /-S (L)

1 242
Download 242 pages 31.85 Kb
Page 154
Image 154

Operating Instructions

COMPAX-M / -S

Digital inputs and outputs

 

Idle after stop or break

Mark missing after maximum feed length

In data record memory mode

Caption:

O6

O6="1" indicates that the axis is at a standstill due to a STOP (I6) or BREAK (I1&I6).

O6 is reset when the axis moves again.

O16

Only assigned if mark reference is activated (P35=1).

With "0", the mark disappears once the maximum feed length is reached (see Page 100)

8.6.1.8 Diagrams:

I3

 

 

 

 

 

 

 

 

 

 

 

 

 

Jog-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

I5

 

 

 

 

 

 

 

 

 

 

 

 

t

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Start

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

I6

 

 

 

 

 

 

 

 

 

 

 

 

t

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Stop

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V

 

 

 

 

 

 

 

 

 

 

 

 

t

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

t

 

 

 

 

 

 

 

 

 

 

 

 

O4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ready

 

 

 

 

 

 

 

 

 

 

 

 

 

to Start

 

 

 

 

 

 

 

 

 

 

 

O5

 

 

 

 

 

 

 

 

 

 

 

 

t

 

 

 

 

 

 

 

 

 

 

 

Progr. target

 

 

 

 

 

 

 

 

 

 

 

 

 

pos. reached

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

O6

 

 

 

 

 

 

 

 

 

 

 

 

t

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Out of action

 

 

 

 

 

 

 

 

 

 

 

 

 

after stop

 

 

 

 

 

 

 

 

 

 

 

0

1

2

3

4

5

6

7

8

t

0 COMPAX ready for new start.

1 When using START at input I5, the outputs O4 and O5 are reset. The axis moves. 2 Interruption using STOP at input I6. After idle, message at output O6 (3).

4 START using I5. Positioning process is continued.

5 Positioning process ended. Message via O4 and O5="1".

6 Manual processing of axis. O5 and O4 ="0".

7 Specification for manual processing ended. Drive decelerates.

8 Manual process ended. Drive at standstill. Ready message for output O4 is set.

154

Page 154
Image 154