Switch-on status

COMPAX-M / -S

5. Switch-on status

5.1Configuration when supplied

When supplied, COMPAX is not configured. Parameter P149 is set to "0": P149="0": COMPAX is not configured and switches to OFF mode when switched

on (24V DC and operating voltage) (motor switched off). In addition to this, when switched on, all parameters (apart from bus settings P194, P195, P196 and P250) are set to their default values.

P149="1": COMPAX is configured and once switched on (24V DC and operating voltage) tries to engage the motor.

5.2Commissioning

Meaning of LEDs on the front panel

COMPAX-M / -S

LED

Color

Meaning, when switched on

Ready

green

24V DC present and initialization complete

Error

red

COMPAX - Error (E1...E56) present or COMPAX is

 

 

initialized.

Mains module

LED

LED

Possible errors

red

green

 

Error

Ready

 

off

on

no errors

on

off

Heat sink temperature too high or

 

 

error in logic voltage (24V DC too low or unit is defective)

 

 

Emergency stop is activated and ready contact is

 

 

released.

on

on

Ballast switching unit overload or

 

 

undervoltage (<100V DC or <80V AC).

COMPAX 1000SL

Status

Red LED (H2)

Green LED (H1)

24V not available

off

off

24V are switched on, boot up

on

off

Unit OFF

off

blinking

Unit error; drive switched off

on

blinking

Unit error; drive powered

on

on

Unit RUNNING

off

on

Caution!

If there is no control voltage, no displays will appear to indicate that operating voltage is present.

Note: With Error E40, external enabling is missing with COMPAX 45XXS, COMPAX 85XXS and COMPAX 1000SL (Hardware input).

10

Page 10
Image 10
Parker  Products COMPAX-M /-S (L) manual Switch-on status, Configuration when supplied, Commissioning, Compax-M / -S Led