Switch-on status

COMPAX-M / -S

5.3Equipment replacement

Previous software V2.0

!Procedure for copying the complete COMPAX setting onto a new unit

!Start ServoManager.

!Connect old COMPAX via RS232.

!Use menu "Insert: Axis: From controller" to set up an axis which contains all

COMPAX settings (all parameters: including system parameters, data records and (with COMPAX XX70) existing curves).

!Connect new COMPAX.

!Use menu "Online: Download" to transfer data (without system parameters1) into the new COMPAX.

Transferring system parameters

!Call up ParameterEditor (Menu: PC Tools: ParameterEditor)

!Use menu "Online: Copy" menu to transfer all parameters (including system parameters) to COMPAX.

Previous software V2.0

Procedure for copying the complete COMPAX setting onto a new unit

!Start ServoManager.

!Connect old COMPAX via RS232.

!Use menu "Insert: Axis: New" to set up a new axis.

!Use menu "Online: Upload" to load all COMPAX settings (all parameters: including system parameters, data records, and (in COMPAX XX70) existing curves) into the new axis.

!Connect new COMPAX.

!Use menu "Online: Download" to transfer data (without system parameters) into the new COMPAX.

Transferring system parameters

!Call up ParameterEditor (Menu: PC Tools: ParameterEditor)

!Use menu "Online: Copy" menu to transfer all parameters (including system parameters) to COMPAX.

1System parameters are internal parameters; you will only obtain an identical COMPAX – setting if these are also transferred.