44
SYMPTOM | PROBLEM | TEST SOLUTION |
Door Sticking | Dirt / dust adheres to the hinges; | - Lift door from its hinges. Lubricate with high temp dry |
| is heated and burns causing | graphite only. Replace. |
| sticking. | - NOTE: Due to the high temperatures that the hinges |
|
| experience, wet lubricants such as oil and WD40 will |
|
| cause the hinge to seize and are therefore not suitable. |
Main burner goes out; pilot goes out.
Thermocouple shorting or faulty. | - | Loosen and tighten thermocouple. |
| - | Clean thermocouple and valve connection. |
| - | Replace thermocouple. |
GS28
SYMPTOM | PROBLEM | TEST SOLUTION |
Main burner goes out; pilot | Venting is spilling. | - Test with spill switch bypassed. |
stays on. |
| - Check for vent blockage. |
GDS28 |
|
|
SYMPTOM | PROBLEM | TEST SOLUTION |
Main burner goes out; pilot | Vent | - Check joint seals and installation. |
goes out. |
|
|
Main burner flame is a | Blockage in vent. | - Remove blockage. In really cold conditions, ice buildup |
blue, lazy, transparent |
| may occur on the terminal and should be removed as |
flame. |
| required. |
| Incorrect installation. | - Ensure vent configuration is within prescribed venting |
|
| parameters |