7
2.3GENERAL INFORMATION
FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN
| GDS28 | GS28 | ||
| NG | LP | NG | LP |
|
|
|
|
|
Altitude (FT) | ||||
|
|
|
|
|
Max. Input (BTU/HR) | 30,000 | 26,000 | 30,000 | 26,000 |
|
|
|
|
|
Max. Output (BTU/HR) | 25,500 | 22,360 | 24,600 | 21,600 |
|
|
|
|
|
Max. Steady State | 85% | 86% | 82% | 83% |
Efficiency (w/the fan |
|
|
|
|
on) |
|
|
|
|
Max. A.F.U.E. | 76% | 77% |
|
|
|
|
|
|
|
Min. Inlet Gas Supply | 4.5" Water Column | 11" Water Column | 4.5" Water Column | 11" Water Column |
Pressure |
|
|
|
|
|
|
|
|
|
Max. Inlet Gas Supply | 7" Water Column | 13" Water Column | 7" Water Column | 13" Water Column |
Pressure |
|
|
|
|
|
|
|
|
|
Manifold Pressure | 3.5" Water Column | 10" Water Column | 3.5" Water Column | 10" Water Column |
(Under Flow |
|
|
|
|
Conditions) |
|
|
|
|
When the appliance is installed at elevations above 4,500 ft, and in the absence of specific recommendations from the local authority having jurisdiction, the certified high altitude input rating shall be reduced at the rate of 4% for each additional 1,000 ft.
Change in flame appearance from "HI" to "LO" is more evident in natural gas than in propane.
Expansion / contraction noises during heating up and cooling down cycles are normal and to be expected.
This appliance may be installed in an aftermarket permanently located, manufactured mobile home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
This appliance is approved for bedroom and