27
4.7.2 INSTALLING "B" VENT
Follow the instructions of the "B" vent manufacturer for chimney installation.
A.Remove and discard the two combustion air cover plates
and gaskets located on the rear panel of the appliance.
B. | Replace the four screws per side to secure the rear |
|
| panel to the appliance. |
|
C. | Remove the spill switch bracket from the rear of the | COMBUSTION AIR COVER |
| adapter. | |
| PLATES AND GASKET | |
|
| |
D. | Gently pull the two wire terminals (located inside the 7" |
|
| flue collar at the top of the appliance) out approximately |
|
| 8". |
|
E. | Bring the wires through the lower hole in the adapter and |
|
| out the spill switch opening. To pass the wires through the |
|
| hole more easily, temporarily tape the two terminals together. |
|
F. | With the spill switch opening aligned to the back of the | ADAPTER |
| appliance, push the crimped edge of the adapter in to the | |
| appliance flue collar. | SPILL |
|
| |
G. | Connect the wire terminals to the spill switch and | SWITCH |
|
the bracket.
H.Secure the terminal block into place as shown with the screw
| supplied. |
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
I. | Unscrew the wire access cover plate from the rear right hand |
|
|
| ||
| side below the firebox. Remove and discard the gasket. |
|
|
| ||
| Remove the knockout from the cover plate and insert the |
|
|
| ||
| protective bushing. Pull both spill switch wires through the |
|
|
| ||
| bushing taking up any slack. Replace the cover plate. Connect one wire end to the terminal block and | |||||
| the other end to terminal 1 of the gas valve. Connect the two wires running down the left side of the | |||||
| unit from the on/off switch to the remaining tab on the terminal block and to terminal 3 on the gas valve. | |||||
| For aesthetics, the adapter |
|
|
|
|
|
| has been designed to accept a |
|
|
|
|
|
| standard matte black 7" stove |
|
|
|
|
|
| pipe and the decorative band |
|
| WIRE ACCESS | ||
| (standard with the |
|
| |||
|
|
| COVER PLATE | |||
| Both are available from your local | TERMINAL BLOCK | ||||
|
|
|
|
authorized dealer / distributor.
4.7.3 B-VENT
Attach the
ATTACH THIS LABEL IN THE CONTROL AREA OF THE FIREPLACE.
THIS FIREPLACE HAS BEEN CONVERTED TO A ‘B’VENT MODEL.
ATTACHEZ CET ETIQUETTE DANS LA REGION DE CONTROLE DU FOYER.
CEFOYERAETECONVERTIAUNMODELEASYSTEMED’EVACUATION‘B’.