3.8TOP EXIT HORIZONTAL TERMINATION

3.8TOP EXIT HORIZONTAL TERMINATION

(HT) < (VT)

Simple venting configuration (only one 90° elbow)

39 40

15

See graph to determine the required vertical rise VT for the required horizontal run HT.

30 V2

REQUIRED

VERTICAL 20

RISE IN

FEET VT 10 Manual background

0

2.5

5

7.5

10

12.5

15

17.5

20

HORIZONTAL VENT RUN PLUS OFFSET IN

FEET HT

The shaded area within the lines represents

acceptable values for HT and VT

For vent configurations requiring more than one 90° elbow, the following formulas apply:

Formula 1: HT < VT

Formula 2: HT + VT < 40 feet

Example 1:

V1

= 3 FT

V2

= 8 FT

VT = V1 + V2= 3 FT + 8 FT = 11 FT

H1

= 2.5 FT

H2

= 2 FT

HR

= H1 + H2 = 2.5 + 2 = 4.5 FT

HO = .03 (three 90° elbows - 90°) = .03 (270° - 90°) = 5.4 FT

HT = HR + HO = 4.5 + 5.4 = 9.9 FT HT + VT = 9.9 + 11 = 20.9 FT

Formula 1: HT < VT

9.9< 11

Formula 2: HT + VT < 40 FT

20.9< 40

Since both formulas are met, this vent configuration is acceptable.

90°Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background H2

V2

90°Manual backgroundManual backgroundManual backgroundManual backgroundManual background

90°Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundH1

V1

16.1A

W415-0153 / B / 06.10.10

Page 15
Image 15
Napoleon Fireplaces GDS28P manual 3.8TOP EXIT HORIZONTAL TERMINATION, V2 90 90H1