We suggest that our gas

6

THIS GAS APPLIANCE SHOULD BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER to conform with local codes. Installation practices vary from region to region and it is important to know the specifics that apply to your area, for example in Massachusetts State:

This product must be installed by a licensed plumber or gas fitter when installed within the commonwealth of Massachusetts.

The appliance damper must be removed or welded in the open position prior to installation of a appliance insert or gas log.

The appliance off valve must be a “T” handle gas cock.

The flexible connector must not be longer than 36 inches.

A Carbon Monoxide detector is required in all rooms containing gas fired appliances.

The appliance is not approved for installation in a bedroom or bathroom unless the unit is a direct vent sealed combustion product.

The installation must conform with local codes or, in

We suggest that our gas

absence of local codes, the National Gas and Propane

hearth products be installed

Installation Code CSA B149.1 in Canada, or the National

and serviced by professionals

Fuel Gas Code, ANSI Z223.1 / NFPA 54 in the United

States. Suitable for mobile home installation if installed in

who are certified in the U.S.

accordance with the current standard CAN/CSA Z240MH

by the National Fireplace

Series, for gas equipped mobile homes, in Canada or

Institute® (NFI) as NFI Gas

ANSI Z223.1 and NFPA 54 in the United States.

Specialists

 

As long as the required clearance to combustibles is

www.nficertified.org

maintained, the most desirable and beneficial location for an appliance is in the center of a building, thereby allowing the most efficient use of the heat created. The location of windows, doors and the traffic flow in the room where the appliance is to be located should be considered. If possible, you should choose a location where the vent will pass through the house without cutting a floor or roof joist.

If the appliance is installed directly on carpeting, vinyl tile or other combustible material other than wood flooring, the appliance shall be installed on a metal or wood panel extending the full width and depth.

If the optional fan or blower is installed, the junction box must be electrically connected and grounded in accordance with local codes, use the current CSA C22.1 Canadian Electrical Code in Canada or the ANSI/ NFPA 70 National Electrical code in the United States.