3.10 VERTICAL THROUGH EXISTING CHIMNEY
This appliance is designed to be attached to a 3" co- linear flexible vent system running the full length of a masonry chimney.
The flexible vent pipe accommodates any contours of |
|
a masonry chimney, however, it is necessary to keep |
|
the flexible vent pipe as straight as possible. The inlet |
|
air collar of the termination cap must be connected to |
|
the air intake pipe. | AIR |
| |
Use Simpson Duravent Chimney Liner Termination | INTAKE |
Kit - 923GK (Base plate and | PIPE |
Adaptor. |
|
Follow manufacturers (Simpson |
|
installation instructions. |
|
When installing the appliance to this system, |
|
Duravent vent components must be used. You must |
|
start with a Duravent adaptor, GDS924N, directly off |
|
the appliance. The GDS924N is only available at your |
|
local authorized dealer / distributor. |
|
19
EXHAUST
FLUE
PIPE
FLEX
VENT
PIPE
40 FEET MAXIMUM 3 FEET MINIMUM
62.5