3.10 VERTICAL THROUGH EXISTING CHIMNEY

3.10 VERTICAL THROUGH EXISTING CHIMNEY

This appliance is designed to be attached to a 3" co- linear flexible vent system running the full length of a masonry chimney.

The flexible vent pipe accommodates any contours of

 

a masonry chimney, however, it is necessary to keep

 

the flexible vent pipe as straight as possible. The inlet

 

air collar of the termination cap must be connected to

 

the air intake pipe.

AIR

 

Use Simpson Duravent Chimney Liner Termination

INTAKE

Kit - 923GK (Base plate and Co-Linear to Co-Axial

PIPE

Adaptor.

 

Follow manufacturers (Simpson Dura-Vent)

 

installation instructions.

 

When installing the appliance to this system,

 

Duravent vent components must be used. You must

 

start with a Duravent adaptor, GDS924N, directly off

 

the appliance. The GDS924N is only available at your

 

local authorized dealer / distributor.

 

19

EXHAUST

FLUE

PIPE

FLEX

VENT

PIPE

40 FEET MAXIMUM 3 FEET MINIMUM

62.5

W415-0153 / B / 06.10.10