Napoleon Fireplaces GDS28P manual 8.2BLOWER REPLACEMENT

Models: GDS28P

1 48
Download 48 pages 52.5 Kb
Page 37
Image 37
8.2BLOWER REPLACEMENT

37

8.2BLOWER REPLACEMENT

Blower replacement may be done through either the firebox or from the rear of the unit. Using the rear panel is recommended.

INSTALLATION THROUGH THE REAR PANEL :

Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background BLOWER

Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background redManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background blackManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background

FOR MODEL GDS28

 

white

 

 

THERMAL

Turn off the electrical power and the gas supply to the

 

SWITCH

 

 

appliance.

VARIABLE

 

 

Remove the two combustion air covers and gaskets held on with 4

 

 

SPEED

 

screws each. Remove the rear panel held in place with 6 screws.

 

 

 

SWITCH

Remove the 2 screws holding the blower to its mounting plate. Disconnect

 

 

the two blower wires.

 

 

Replace the blower and reconnect the two wires.

 

 

 

When replacing the rear panel, ensure that the wires

 

SCREWS

 

are neither pinched nor interfere with the blower

 

 

operation. Ensure that the combustion air cover

 

 

 

plates and gaskets are properly installed and sealed.

 

 

FOR MODEL GS28

 

BLOWER

 

 

Turn off the electrical power and the gas supply to

AIR INTAKE MANIFOLDS

 

the appliance.

 

 

Remove the 8 screws securing the air intake

manifolds to the rear panel. Remove the rear panel held in place with 6 screws.

Remove the 2 screws holding the blower to its mounting plate. Disconnect the two blower wires.

Replace the blower and reconnect the two wires. When replacing the rear panel, ensure that the wires are neither pinched nor interfere with the blower operation. Re-secure the air intake manifolds.

INSTALLATION THROUGH THE FIREBOX:

REPLACEMENT BLOWER ACCESS GASKET IS REQUIRED.

Turn off the electrical power and the gas supply to the

 

appliance.

 

Open the lower control door, the two side doors, and the

 

 

fire viewing door. Remove the logs.

 

Remove the blower access plate held on with 8 screws.

SCREWS

Disconnect the two blower wires. Remove the blower

 

 

bracket held on with 2 screws.

 

Replace the blower using the existing bracket. Replace the

 

 

bracket/blower assembly on the unit.

BLOWER ACCESS

Reconnect the two wires. Hold the replacement gasket in

PLATE

 

place and reattach the blower access plate. Replace the

 

 

 

logs. Close all doors.

 

Turn the gas supply and electricity back on.

Because the blower is thermally activated, when turned on, it will automatically start approximately 15-30 minutes after lighting the stove and will run for approximately 30-45 minutes after the stove has been turned off. Use of the fan increases the output of heat.

Drywall dust will penetrate into the blower bearings causing irreparable damage and must be prevented from coming into contact with the blower or its compartment.

Any damage resulting from this condition is not covered by the warranty policy.

W415-0153 / B / 06.10.10