Process interfaces

9.6.5 HEDA interface

HEDA using option A1 (e.g. A4 for COMPAX 1000SL) for COMPAX XX00 and the interpolation module IPM as master,

or

for a COMPAX – COMPAX –coupling with the unit variants COMPAX XX00, COMPAX XX60 and COMPAX XX70, see from Page 168).

Implementing tracking and contouring tasks with the HAUSER interpolation module (IPM) for PCs and industrial PCs.

Communication occurs via the HEDA interface, a rapid synchronous serial interface.

Functional scope of the IPM and COMPAX network:

!contours can be stored for up to 9 axes with up to 100000 points.

!16 zero-related digital outputs.

!Exchange of data between 9 axes within 1ms (setpoint values, auxiliary functions, position, lag error, speed, torque)

!Freely programmable inputs and outputs

(Once enabled via P221, P222 and P225, and allocation of outputs to HEDA via P245 and P245; see Page 139).

!internal data record memory can still be used to its full extent

!can be independently operated as a single axis positioning system

Physical transfers:

RS485 level (counter-cycle driver);

DC decoupled using an optical coupler;

Cycle frequency: 5 Mbit/s.

Working with the HEDA interface is described from Page 168, where used with the interpolation module IPM, a special manual is available!

9.6.6D/A monitor (D1) (option not available with COMPAX 1000SL)

The D/A monitor offers you the option of outputting COMPAX internal measurement and intermediate parameters in the form of analogue voltage in the range of ± 10V. For description, see Page 58.

185

Unit

hardware

 

 

Connector

assignment / cable

Technical data

 

 

 

Configuration

 

 

 

Positioning and

control functions

 

 

Optimization

functions

 

 

Interfaces

 

 

 

Accessories /

options

 

 

Status

 

 

 

Parameter

 

 

 

Error list

 

 

 

Page 185
Image 185
Parker  Products COMPAX-M /-S (L) manual Process interfaces Heda interface