Model SB1027 | M A I N T E N A N C E | For Machines Mfg. Since 8/09 |
Table Elevation Leadscrew
Grease Type | NLGI 2 or Equivalent |
Grease Amount | Thin Coat |
Check/Add Frequency | 40 hrs. of Operation |
Elevate the table all the way up, then use mineral spirits to clean any debris and
Leadscrew
Grease
Fitting
Figure 52. Table elevation leadscrew and grease
fitting.
Power Feed Gears | |
Grease | |
Grease Amount | Two Pumps of Grease Gun |
Check/Add Frequency | 40 hrs. of Operation |
Tool Needed | Qty |
Wrench 19mm | 1 |
To lubricate the power feed gears:
1.DISCONNECT MACHINE FROM POWER!
2.Remove the hex nut and ball handle from the power unit end of the longitudinal leadscrew (see Figure 53).
Graduated Dial Ring | Leadscrew |
|
Retaining Ring
Figure 53. Power feed ball handle removed.
3.Unthread and remove the knurled retaining ring and graduated dial ring from the end of the leadscrew.