Model SB1027

M A I N T E N A N C E

For Machines Mfg. Since 8/09

Failure to follow reasonable lubrication practices as instructed in this manual for the mill could lead to premature failure of the mill and will void the warranty.

Quill

Oil Type

Mobil Vactra 2 or ISO 68 Equivalent

Oil Amount

Fill Oil Cup

Check/Add Frequency

4 hrs. of Operation

Lift the oil cup cap shown in Figure 46 to fill the oil cup with lubricant.

Table Ways (One-Shot Oiler)

Oil Type

Mobil Vactra 2 or ISO 68 Equivalent

Oil Amount

One Pull of Pump Handle

Check/Add Frequency

...........4–8 hrs. of Operation

The one-shot oiler is connected to a series of aluminum tubes that carry the lubricant to wear points along the table horizontal and vertical ways. After using the oiler pump handle shown in Figure 47, move the table through all paths of movement to evenly distribute the lubricant.

Use the sight glass on the side of the oiler to know when to re-fill the reservoir.

Quill Oil Cup

Figure 46. Quill oil cup location.

Reservoir Cap

Pump

Handle

Sight

Glass

Figure 47. One-shot oiler controls.