Keys Fitness 315-00106 Error Messages, To Change Unit of Measure from Standard to Metric

Page 16

Console Instructions

from the beginning of the profile. All workout data will continue to add to previous values. If you burned 150 calories during original program this value will not reset to 0. Unit will automatically shut off after 4 minutes of inactivity. Press any button to bring the console back to full functionality.

ERROR MESSAGES -

The message center will display “motor error” message whenever the brake motor was unable to move to its target position within 2 seconds.

Each time the CG1 is powered on, the console will check the brake motor status. If the brake motor does not reply, then the console will display the error message “MOTOR ERROR” immediately and disable button operation until power is reset.

To clear this error message plug and unplug the unit.

TO CHANGE UNIT OF MEASURE FROM STANDARD TO METRIC -

Press the PAUSE/RESET button for 2 seconds. Use the +/- buttons to change unit of measure. Press ENTER/SCAN to confirm setting.

HEART RATE PROGRAMS

HEART RATE PROGRAMS -

(See MONITORING YOUR HEART RATE Section for more information)

Heart rate control programs are designed to automatically change resistance to keep your heart rate at a predetermined level based on the selected Heart Rate program. Each Heart Rate pro- gram is designed with a specific goal in mind.

If no Heart Rate signal is detected for 10 seconds, the message center will show “NO DETECTED HR”. If this continues for 40 seconds, the message center will show “ABORT PROGRAM” for 3 seconds then interrupt the Heart Rate Control program and return to Program Mode.

HOW HEART RATE PROGRAMS WORK -

Delta Heart Rate (DHR) = Beats per minute difference between Target Heart Rate and Current Heart Rate

The Heart Rate Programs will behave in the following manner:

DHR <= 5 Tension Level stays the same, Message Center will show “IN HR TARGET” for 3 seconds then toggle back to workout information.

DHR >5 Tension Level decreases. If the current Tension Level is 1, then the Message. Window will display “stride slower” for 3 seconds. The Console will check the user’s Heart Rate every 40 seconds and adjust the Tension Level to fit the Target Heart Rate.

DHR < 5 Tension Level will increase. If the current Tension Level is 20, the Message window will show “stride faster” for three seconds. The Console will check the user’s Heart Rate every 40 seconds and adjust the Tension Level to fit the Target Heart Rate.

16

Image 16
Contents Customer Service 888 Table of Contents Important Safety Information Safety Precautions and TipsImportant Safety Information Assembly Cover Sleeve Bracket Cover Pulse Wire Congratulations Button Overview Start Console InstructionsENTER/SCAN Program PAUSE/RESETMessage Window Profile Window Shows current lap Mountain Hill Random User Profiles During OperationError Messages To Change Unit of Measure from Standard to MetricHeart Rate Programs HOW Heart Rate Programs WorkHeart Rate Console Instructions Monitoring Your Heart Rate Monitoring Your Heart RateWarm Up Exercises Exercise GuidelinesTrouble Shooting Guide CLEANING/MAINTENANCEParts List CG1 Parts List Rev aExploded View Warranty Information Residential and Personal Use Limited WarrantyCustomer Service