PROBLEM: The walking belt is off-center or slips when walked on

SOLUTION: a. If the walking belt has shifted to the left, first re- move the key and UNPLUG THE POWER CORD. Using the allen wrench, turn the left rear roller adjust- ment bolt clockwise, and the right bolt counterclock- wise, 1/4 of a turn each. Be careful not to overtighten the walking belt. Plug in the power cord, insert the key and run the treadmill for a few minutes. Repeat until the walking belt is centered.

b. If the walking belt has shifted to the right, first re- move the key and UNPLUG THE POWER CORD. Using the allen wrench, turn the left rear roller adjust- ment bolt counterclockwise, and the right bolt clock- wise, 1/4 of a turn each. Be careful not to overtighten the walking belt. Plug in the power cord, insert the key and run the treadmill for a few minutes. Repeat until the walking belt is centered.

c. If the walking belt slips when walked on, first re- move the key and UNPLUG THE POWER CORD. Using the allen wrench, turn both rear roller adjust- ment bolts clockwise, 1/4 of a turn. When the walking belt is correctly tightened, you should be able to lift each side of the walking belt 3 to 4 inches off the walking platform. Be careful to keep the walking belt centered. Plug in the power cord, insert the key and run the treadmill for a few minutes. Repeat until the walking belt is properly tightened.

a

b

c

PROBLEM: The walking belt slows when walked on

SOLUTION: a. Use only a single-outlet surge suppressor that is UL 1449 listed as a transient voltage surge sup- pressor (TVSS). The surge suppressor must have a UL suppressed voltage rating of 400 volts or less and a minimum surge dissipation of 450 joules. The surge suppressor must be electrically rated for 120 volts AC and 15 amps.

b. If the walking belt is overtightened, treadmill perfor- mance may decrease and the walking belt may be permanently damaged. Remove the key and UN- PLUG THE POWER CORD. Using the allen wrench, turn both rear roller adjustment bolts counterclock- wise, 1/4 of a turn. When the walking belt is properly tightened, you should be able to lift each side of the walking belt 3 to 4 inches off the walking platform. Be careful to keep the walking belt centered. Plug in the power cord, insert the key and run the treadmill for a few minutes. Repeat until the walking belt is properly tightened.

b

3ÓÐ4Ó

Rear Roller Adjustment Bolts

c. If the walking belt still slows when walked on, please call our toll-free HELPLINE.

13

Image 13
Contents SEARS, Roebuck and CO., Hoffman ESTATES, IL Model No Serial NoImportant Precautions Table of ContentsPage Left Right Side Before YOU BeginAssembly requires the included allen wrench AssemblyPhillips Page HOW to Plug in the Power Cord Operation and AdjustmentPerformant Lubetm Walking Belt Step by Step Console Operation Diagram of the ConsoleCALS/FAT Cals HOW to Fold the Treadmill for Storage HOW to Fold and Move the TreadmillHOW to Move the Treadmill HOW to Lower the Treadmill for USE Problem The power turns off during use Maintenance and TROUBLE-SHOOTINGTop 3ÓÐ4Ó Exercise Intensity Conditioning GuidelinesWorkout Guidelines Part LISTÑModel No 22 21 106 5356 104 47 50 Exploded DRAWINGÑModel No Model No Full 90 DAY WarrantySEARS, Roebuck and CO., Dept WA, Hoffman ESTATES, IL