ProForm 795 user manual Problem The heart rate monitor does not function properly

Page 23

PROBLEM: The walking belt is off-center or slips when walked on

SOLUTION: a. If the walking belt has shifted to the left, first re- move the key and UNPLUG THE POWER CORD. Using the allen wrench, turn the left rear roller adjust- ment bolt clockwise, and the right bolt counterclock- wise, 1/4 of a turn each. Be careful not to overtighten the walking belt. Plug in the power cord, insert the key and run the treadmill for a few minutes. Repeat until the walking belt is centered.

b. If the walking belt has shifted to the right, first re- move the key and UNPLUG THE POWER CORD. Using the allen wrench, turn the left rear roller adjust- ment bolt counterclockwise, and the right bolt clock- wise, 1/4 of a turn each. Be careful not to overtighten the walking belt. Plug in the power cord, insert the key and run the treadmill for a few minutes. Repeat until the walking belt is centered.

c. If the walking belt slips when walked on, first re- move the key and UNPLUG THE POWER CORD. Using the allen wrench, turn both rear roller adjust- ment bolts clockwise, 1/4 of a turn. When the walking belt is correctly tightened, you should be able to lift each side of the walking belt 3 to 4 inches off the walking platform. Be careful to keep the walking belt centered. Plug in the power cord, insert the key and run the treadmill for a few minutes. Repeat until the walking belt is properly tightened.

a

b

c

PROBLEM: An error code (E1, E20, E21, E22, or E23) appears on the console

SOLUTION: a. If an error code appears in one of the displays of the console, remove the key from the console, wait for a moment, and then reinsert the key. If the error code appears again, call our toll-free HELPLINE. Do not use the treadmill until the problem is corrected.

PROBLEM: The heart rate monitor does not function properly

SOLUTION: a. If the heart rate monitor does not function properly, refer to CHEST PULSE SENSOR TROUBLE- SHOOTING on page 7.

b. The CR 2032 battery may need to be replaced.

To replace the battery, locate the battery cover on the back of the sensor unit. Insert a coin into the slot in the cover, turn the cover counterclockwise, and remove it.

Remove the old battery and insert a new CR 2032 battery, making

 

 

 

 

sure that the battery is turned so the writing is on top. Make sure that

 

 

 

 

the rubber gasket is in place in the sensor unit. Replace the battery

 

 

 

 

 

CR 2032

cover and turn it clockwise to close it.

 

Battery

 

 

 

 

 

 

 

 

 

 

 

 

Rubber

 

 

Gasket

 

 

 

 

 

 

 

 

 

 

 

23

Image 23
Contents Model No Serial No Important Precautions Table of ContentsKeep hands and feet away from Left Right Side Before YOU BeginAssembly requires a phillips screwdriver not included AssemblyPage Chest Pulse Sensor TROUBLE-SHOOTING HOW to USE the Chest Pulse SensorHOW to PUT on the Chest Pulse Sensor Care and MaintenanceHand Pulse Sensor TROUBLE-SHOOTING HOW to USE the Hand Pulse SensorCR 2032 battery may need to be replaced BatteryPerformant Lubetm Walking Belt Operation and AdjustmentHOW to Plug in the Power Cord Features of the Console Diagram of the ConsoleHOW to Turn on the Power HOW to USE the Manual Mode CALS./FAT Cals INCLINE/AGEPress the Start button to start the program HOW to USE the Speed ProgramsSelect the desired speed program Select the desired heart rate program HOW to USE the Heart Rate ProgramsSelect the Fitness Test program HOW to USE the Fitness Test ProgramTreadmill is set at 1.5%. Remove the key Chest Pulse Sensor TROUBLE-SHOOTING HOW to Create a Custom Program Press the Start button HOW to USE a Custom ProgramWhen the program is completed, remove the key HOW to Select the Information ModeHOW to Fold the Treadmill for Storage HOW to Fold and Move the TreadmillHOW to Adjust the Firmness of the Walking Platform HOW to Lower the Treadmill for USE HOW to Move the TreadmillProblem The walking belt slows when walked on Maintenance and TROUBLE-SHOOTINGProblem The power turns off during use Problem The heart rate monitor does not function properly Workout Guidelines Conditioning GuidelinesExercise Intensity Suggested Stretches Key Part Qty Description R1197AKey Part Qty Description Exploded DRAWING-Model No Pages 26 To identify SEARS, Roebuck and CO., Dept WA, Hoffman ESTATES, IL Full 90 DAY WarrantyModel No
Related manuals
Manual 36 pages 43.52 Kb