MAINTENANCE AND TROUBLESHOOTING
Inspect and properly tighten all parts of the exercise cycle regularly. Replace any worn parts immediately.
To clean the exercise cycle, use a damp cloth and a small amount of liquid dish soap. IMPORTANT: To avoid damaging the console, keep liquids away from the console and keep the console out of direct sunlight.
BATTERY REPLACEMENT
With the left side shield removed, locate the Reed Switch (43). Turn the Crank (31) until the Magnet (38) is aligned with the Reed Switch. Next, loosen, but do not remove, the indicated M4 x 16mm Screw (57). Slide the Reed Switch slightly closer to or away from the Magnet, and then retighten the Screw. Turn the Crank for a moment. Repeat until the console displays correct feedback. When the Reed Switch is correctly adjusted, reattach the left side shield and the left pedal.
If the console display becomes dim, the batteries should be replaced; most console problems are the result of low batteries. To replace the batteries, see assembly step 6 on page 7.
HOW TO ADJUST THE REED SWITCH
If the console does not display correct feedback, the reed switch should be adjusted. To adjust the reed switch, you must first remove the Left Side Shield (9). Using an adjustable wrench, turn the Left Pedal (24) clockwise and remove it. Next, remove the seven M4 x 16mm Screws (57) and the M4 x 25mm Screw (45). Then, carefully remove the Left Side Shield.
9 |
57 |
57 |
57 |
45 |
24 |
57 |
31 | 43 |
| 57 |
| 38 |
HANDGRIP PULSE SENSOR TROUBLESHOOTING
If the handgrip pulse sensor does not function properly, see step 5 on page 12.
14