Maintenance continued
CLEANING THE WATER INLET FILTER
•Periodically clean the water inlet filter.
•Remove the power plug from the wall socket.
•Turn off the water taps.
•Separate the inlet hose and remove the mesh filter.
• Clean the filter with an old toothbrush and
CLEANING THE DRAIN FILTER
Place a shallow con- | Turn the filter cap in an | Pull the filter assembly |
tainer under the drain- | anticlockwise direction. | out. |
filter to collect any |
|
|
residual water spillage. |
|
|
GROOVE
| Tighten the cap by turn- | ||
Clean the drain filter. | guides ensuring that | ing it in a clockwise | |
the groove in the filter | direction. | ||
| |||
| aligns with the guide rib. |
|
Technical specifications
Power source AC
Power consumption 430 W
Dimensions ( W x H x D ) in mm. 598 x 956 x 643
Unit weight 43kg
Standard water consumption 207 litres
Water level for High, Medium, Low, Small 88, 75, 61, 48 litres
Wash mode Double action type Air bubble + Pulsator.