Defy Appliances Electrologic 920 owner manual Installation

Page 4

Installation

UNPACKING

Remove all packaging and dispose of it in a responsible manner.

Open the wash-tub lid and remove all the accessories stored in the drum.

Do not attempt to operate the machine while any of the packaging is still in place.

POSITIONING

The machine should be installed in a well ventilated place, away from direct sunlight.

Hot and cold water taps should be located within 1 metre of the inlet valves.

Positioned the machine on a flat and stable uncarpeted

floor capable of supporting the fully loaded washer.

An adjustable levelling foot is located at the right front of the machine and may be turned in or out to achieve stability. An unstable machine will vibrate and generate excessive noise.

DRAIN HOSE

Drain

outlet

Connect the drain hose to the drain outlet at the rear of the machine and secure it with the hose clamp supplied.

Hook the outlet end of the drain hose over the lip of a sink or outlet pipe.

SINK OR LAUNDRY TUB DRAIN

Drain hose Hose clamp

A

The top lip of the sink must be at least 860mm (A) above floor level and not higher than 1300mm.

PIPE DRAIN

B

 

The minimum inside diameter of the pipe drain should be 30mm and the pipe should be able to drain 30 litres per minute.

The top lip of the pipe should be at least 860mm (B) above floor level and not higher than 1300mm.

Page 4

Image 4
Contents You can rely on Defy Accessories FeaturesCongratulations Safety precautions Installation Connecting the Water Inlet Hoses Electrical installationInlet Hoses Loading the machine PreparationSorting LoadingFunctions of the controls Medium High Small LOWProgramme selection Time delayed start Customising programmesSelecting the Wash Time Selecting the Number of RinsesOperation procedure Before ANY of the Wash Options are Selected YOU Must FirstLoading Detergent Adding BleachMaintenance Cleaning the Water Inlet Filter Technical specificationsCleaning the Drain Filter Problem Trouble shootingCheck Service Centres Warranty Part Number 062