Electrolux EHG 7822 manual Commissioning, Pressure Testing, Procedure, Minimum adjustment, Screw

Page 29

electrolux 29

Commissioning

When the hob has been fully installed it will be necessary to check the minimum flame setting. To do this, follow the procedure below.

!1) Turn the gas tap to the MAX position and ignite.

2)Set the gas tap to the MIN flame position then turn the control knob from MIN to MAX several times. If the flame is unstable or is extinguished follow the procedure below.

Procedure:

 

 

 

! 1)

toReMIN.-ignite the burner and set

 

2)

Remove the control knob.

 

3)

To adjust, use a thin bladed

 

 

screwdriver

and turn

the

 

 

adjustment

screw

(see

 

 

diagram) until the flame is

 

 

steady and

does

not

Minimum adjustment

 

extinguish, when the knob is

 

screw

 

turned from MIN to MAX.

Repeat this procedure for all burners.

Pressure Testing

The pressure testing must becarried out on the burners.

!Proceed as follows:

1)Remove the pan supports and the burner caps and crowns.

2)Fit manometer tube over the injector.

3)Turn on the burner gas supply and ignite another burner supply.

The pressure reading should be nominally 20 mbar and must be between 17 mbar and 25 mbar.

4)Turn off the burner supplies.

Image 29
Contents Instruction booklet Electrolux Welcome to the world of Electrolux Contents Installation Important Safety InformationChild Safety During UseService ∀ Environmental Information Description of the Hob Installation Hob burners control knobs OperationLighting the burners Only for model EHGBurner Minimum Maximum Diameter Using the hob correctlyPan Supports Maintenance and CleaningHob Top Ignition electrode BurnersSomething Not Working? SymptomEngineer technical data Instructions for the InstallerType of GAS Location Important safety requirementsInstallation Gas Connection Cut Out Size Building over a kitchen unit with door BuildingBuilding over a cupboard or drawer Fitting the Hob into the Worktop This HOB Must be Earthed Electrical ConnectionsPermanent Connection Wiring Diagram Preliminary Electrical Systems Check Fault FindingEarth Continuity Check Ignition System / Gas Ignition Procedure Pressure TestingMinimum adjustment CommissioningMethod Conversion from Natural Gas to LPGExclusions Standard Guarantee Conditions0870 5 929 Service and Spare PartsEuropean Guarantee Electrolux Electrolux 35693-2001