Whirlpool W10049540 manual Wire connection Power supply cord, Style 2 Direct wire strain relief

Page 10

Put power supply cord through the strain relief. Be sure that the wire insulation on the power supply cord is inside the strain relief. The strain relief should have a tight fit with the dryer cabinet and be in a horizontal position. Do not further tighten strain relief screws at this point.

Style 2: Direct wire strain relief

Unscrew the removable conduit connector and any screws from a ³⁄₄" (1.9 cm) UL listed strain relief (UL marking on strain relief). Put the threaded section of the strain relief through the hole below the terminal block opening. Reaching inside the terminal block opening, screw the removable conduit connector onto the strain relief threads.

A

B

C

A. Removable conduit connector

B. Hole below terminal block opening

C. Strain relief threads

Put direct wire cable through the strain relief. The strain relief should have a tight fit with the dryer cabinet and be in a horizontal position. Tighten strain relief screw against the direct wire cable.

4.Now complete installation following instructions for your type of electrical connection:

4-wire(recommended)

3-wire(if 4-wire is not available)

Electrical Connection Options

If your home has:

And you will be

Go to Section

 

connecting to:

 

4-wire receptacle

A UL listed, 120/

4-wire connection:

(NEMA Type 14-30R)

240-volt

Power supply cord

 

minimum,

 

 

30-amp, dryer

 

 

power supply

 

 

cord*

 

4-wire direct

A fused

4-wire connection:

 

disconnect or

Direct Wire

 

circuit breaker

 

5"

box*

 

 

 

(12.7 cm)

 

 

3-wire receptacle

A UL listed, 120/

3-wire connection:

(NEMA type 10-30R)

240-volt

Power supply cord

 

minimum,

 

 

30-amp, dryer

 

 

power supply

 

 

cord*

 

3-wire direct

A fused

3-wire connection:

 

disconnect or

Direct Wire

 

circuit breaker

 

3¹⁄₂"

box*

 

(8.9 cm)

 

 

*If local codes do not permit the connection of a cabinet-ground conductor to the neutral wire, go to “Optional 3-wire connection” section.

4-wire connection: Power supply cord

IMPORTANT: A 4-wire connection is required for mobile homes and where local codes do not permit the use of 3-wire connections.

BF

A

C DEG

A.4-wire receptacle (NEMA type 14-30R) B. 4-prong plug

C. Ground prong D. Neutral prong

E. Spade terminals with upturned ends F. ¾" (1.9 cm) UL listed strain relief G. Ring terminals

10

Image 10
Contents Electronic Electric Dryer W10049540Table of Contents Dryer Safety Your safety and the safety of others are very importantTools and Parts Installation InstructionsOptions Location Requirements Closet installation Dryer only Dryer DimensionsInstallation spacing for cabinet installation Custom undercounter installation Dryer onlyElectrical Requirements Mobile home Additional installation requirementsMobile home installations require It is your responsibilityIf connecting by direct wire If using a power supply cordIf your outlet looks like this Style 1 Power supply cord strain relief Power Supply Cord Direct WireElectrical Connection Wire connection Power supply cord Style 2 Direct wire strain reliefWire connection Direct wire Remove center silver-colored terminal block screwBDE CG F Optional 3-wire connection Venting Requirements If using an existing vent systemIf this is a new vent system Vent material Alternate installations for close clearances Optional exhaust installationsPlan Vent System Special provisions for mobile home installations Install Vent SystemInstall Leveling Legs Vent system chartLevel Dryer Complete InstallationConnect Vent If the dryer will not start, check the followingStarting Your Dryer Dryer USETo use an Automatic Cycle Control Locked Pausing or RestartingStopping Your Dryer Drying and Cycle TipsStatus Lights CyclesAdditional Features End of Cycle Signal Drying RackCleaning the Dryer Interior Cleaning the Dryer LocationCleaning the Lint Screen Dryer CareVacation and Moving Care Removing Accumulated LintChanging the Drum Light Troubleshooting Dryer OperationStains on load or drum Cycle time too shortLint on load Loads are wrinkledFor assistance and service Assistance or ServiceIf you need replacement parts Accessories U.S.ACall W10049540