Whirlpool W10049540 manual Electrical Connection, Power Supply Cord Direct Wire

Page 9

Electrical Connection

Power Supply Cord

 

Direct Wire

WARNING

Fire Hazard

Use a new UL listed 30 amp power supply cord.

Use a UL listed strain relief.

Disconnect power before making electrical connections.

Connect neutral wire (white or center wire) to center terminal (silver).

Ground wire (green or bare wire) must be connected to green ground connector.

Connect remaining 2 supply wires to remaining 2 terminals (gold).

Securely tighten all electrical connections.

Failure to do so can result in death, fire, or electrical shock.

WARNING

Fire Hazard

Use 10 gauge solid copper wire.

Use a UL listed strain relief.

Disconnect power before making electrical connections.

Connect neutral wire (white or center wire) to center terminal (silver).

Ground wire (green or bare wire) must be connected to green ground connector.

Connect remaining 2 supply wires to remaining 2 terminals (gold).

Securely tighten all electrical connections.

Failure to do so can result in death, fire, or electrical shock.

1.Disconnect power.

2.Remove the hold-down screw and terminal block cover.

C

D

B

A

A.Neutral ground wire

B.External ground conductor screw

C.Center, silver-colored terminal block screw

D.Terminal block cover and hold-down screw

3.Install strain relief.

Style 1: Power supply cord strain relief

Remove the screws from a ³⁄₄" (1.9 cm) UL listed strain relief (UL marking on strain relief). Put the tabs of the two clamp sections into the hole below the terminal block opening so that one tab is pointing up and the other is pointing down, and hold in place. Tighten strain relief screws just enough to hold the two clamp sections together.

A

B

C

D

A. Strain relief tab pointing up

B. Hole below terminal block opening

C. Clamp section

D. Strain relief tab pointing down

9

Image 9
Contents W10049540 Electronic Electric DryerTable of Contents Your safety and the safety of others are very important Dryer SafetyInstallation Instructions Tools and PartsOptions Location Requirements Installation spacing for cabinet installation Dryer DimensionsCloset installation Dryer only Custom undercounter installation Dryer onlyMobile home installations require Mobile home Additional installation requirementsElectrical Requirements It is your responsibilityIf using a power supply cord If connecting by direct wireIf your outlet looks like this Power Supply Cord Direct Wire Style 1 Power supply cord strain reliefElectrical Connection Style 2 Direct wire strain relief Wire connection Power supply cordRemove center silver-colored terminal block screw Wire connection Direct wireBDE CG F Optional 3-wire connection If using an existing vent system Venting RequirementsIf this is a new vent system Vent material Optional exhaust installations Alternate installations for close clearancesPlan Vent System Install Leveling Legs Install Vent SystemSpecial provisions for mobile home installations Vent system chartConnect Vent Complete InstallationLevel Dryer If the dryer will not start, check the followingDryer USE Starting Your DryerTo use an Automatic Cycle Stopping Your Dryer Pausing or RestartingControl Locked Drying and Cycle TipsCycles Status LightsAdditional Features Drying Rack End of Cycle SignalCleaning the Lint Screen Cleaning the Dryer LocationCleaning the Dryer Interior Dryer CareRemoving Accumulated Lint Vacation and Moving CareChanging the Drum Light Dryer Operation TroubleshootingLint on load Cycle time too shortStains on load or drum Loads are wrinkledIf you need replacement parts Assistance or ServiceFor assistance and service Accessories U.S.AW10049540 Call