WARNING

Explosion Hazard

Keep flammable materials and vapors, such as gasoline, away from dryer.

Place dryer at least 18 inches (46 cm) above the floor for a garage installation.

Failure to do so can result in death, explosion, or fire.

Is the dryer located in a room with temperature below 45ºF (7ºC)?

Proper operation of dryer cycles requires temperatures above 45ºF (7ºC).

Is the dryer located in a closet?

Closet doors must have ventilation openings at the top and bottom of the door. The front of the dryer requires a minimum of 1" (2.5 cm) of airspace, and, for most installations, the rear of the dryer requires 5" (12.7 cm). See the Installation Instructions.

Has the Air Only temperature setting been selected? Select the right cycle for the types of garments being dried. See “Additional Features.”

Is the load too large and heavy to dry quickly? Separate the load to tumble freely.

Cycle time too short

WARNING

Excessive Weight Hazard

Use two or more people to move and install dryer. Failure to do so can result in back or other injury.

Is the automatic cycle ending early?

The load may not be contacting the sensor strips. Level the dryer.

Change the dryness level setting on Automatic Cycles. Increasing or decreasing the dryness level will change the amount of drying time in a cycle.

Lint on load

Is the lint screen clogged?

Clean lint screen. Check for air movement.

Stains on load or drum

Was dryer fabric softener properly used?

Add dryer fabric softener sheets at the beginning of the cycle. Fabric softener sheets added to a partially dried load can stain your garments.

Drum stains are caused by dyes in clothing (usually blue jeans). This will not transfer to other clothing.

Loads are wrinkled

Was the load removed from dryer at the end of the cycle?

Was the dryer overloaded?

Dry smaller loads that can tumble freely.

Odors

Have you recently been painting, staining or varnishing in the area where your dryer is located?

If so, ventilate the area. When the odors or fumes are gone from the area, rewash and dry the clothing.

Is the dryer being used for the first time?

The new electric heating element may have an odor. The odor will be gone after the first cycle.

26

Image 26
Contents Electronic Electric Dryer W10049540Table of Contents Dryer Safety Your safety and the safety of others are very importantOptions Installation InstructionsTools and Parts Location Requirements Closet installation Dryer only Dryer DimensionsInstallation spacing for cabinet installation Custom undercounter installation Dryer onlyElectrical Requirements Mobile home Additional installation requirementsMobile home installations require It is your responsibilityIf your outlet looks like this If using a power supply cordIf connecting by direct wire Electrical Connection Power Supply Cord Direct WireStyle 1 Power supply cord strain relief Wire connection Power supply cord Style 2 Direct wire strain reliefWire connection Direct wire Remove center silver-colored terminal block screwBDE CG F Optional 3-wire connection If this is a new vent system Vent material If using an existing vent systemVenting Requirements Plan Vent System Optional exhaust installationsAlternate installations for close clearances Special provisions for mobile home installations Install Vent SystemInstall Leveling Legs Vent system chartLevel Dryer Complete InstallationConnect Vent If the dryer will not start, check the followingTo use an Automatic Cycle Dryer USEStarting Your Dryer Control Locked Pausing or RestartingStopping Your Dryer Drying and Cycle TipsStatus Lights CyclesAdditional Features End of Cycle Signal Drying RackCleaning the Dryer Interior Cleaning the Dryer LocationCleaning the Lint Screen Dryer CareChanging the Drum Light Removing Accumulated LintVacation and Moving Care Troubleshooting Dryer OperationStains on load or drum Cycle time too shortLint on load Loads are wrinkledFor assistance and service Assistance or ServiceIf you need replacement parts Accessories U.S.ACall W10049540