■A level floor with a maximum slope of 1" (2.5 cm) under entire dryer. If slope is greater than 1" (2.5 cm), install Extended Dryer Feet Kit, Part Number 279810. Clothes may not tumble properly and automatic sensor cycles may not operate correctly if dryer is not level.
■For a garage installation, you will need to place the dryer at least 18" (46 cm) above the floor. If using a pedestal, you will need 18" (46 cm) to the bottom of the dryer.
Do not operate your dryer at temperatures below 45ºF (7ºC). At lower temperatures, the dryer might not shut off at the end of an automatic cycle. This can result in longer drying times.
The dryer must not be installed or stored in an area where it will be exposed to water and/or weather.
Custom undercounter installation - Dryer only
0" |
|
|
(0 cm) |
|
|
38" min. |
|
|
(96.52 cm) |
|
|
1"* | 27" | 1"* |
(2.5 cm) | (68.6 cm) | (2.5 cm) |
*Required spacing
Closet installation - Dryer only
Check code requirements. Some codes limit, or do not permit, installation of the dryer in garages, closets, mobile homes or sleeping quarters. Contact your local building inspector.
Installation clearances
The location must be large enough to allow the dryer door to open fully.
Dryer Dimensions
52 ⁹⁄₁₆" (133.16 cm)
| 14" max.* | |
| (35.6 cm) | |
| 18" min.* | |
| (45.72 cm) | |
1"* | 32⁹⁄₁₆" | 5"** |
(2.5 cm)(82.65 cm)(12.7 cm) |
A
48in.2*
(310 cm2)
24in.2*
(155 cm2)
3"*
(7.6 cm)
3"*
(7.6 cm)
B
38"
(96.52 cm)
*32 ⁹⁄₁₆"
(82.65 cm)27"
(68.6 cm)
*Most installations require a minimum 5" (12.7 cm) clearance behind the dryer for the exhaust vent with elbow. See “Venting Requirements.”
Installation spacing for recessed area or closet installation
The following spacing dimensions are recommended for this dryer. This dryer has been tested for spacing of 0" (0 cm) clearance on the sides and rear. Recommended spacing should be considered for the following reasons:
■Additional spacing should be considered for ease of installation and servicing.
■Additional clearances might be required for wall, door and floor moldings.
■Additional spacing should be considered on all sides of the dryer to reduce noise transfer.
■For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable.
■Companion appliance spacing should also be considered.
A. Side view - closet or confined area
B. Closet door with vents
*Required spacing
**For side or bottom venting, 2" (5.1 cm) spacing is allowed.
Recessed or closet installation - Dryer on pedestal
|
|
|
| 14" max.* | |
|
|
|
| (35.6 cm) | |
|
|
|
| 18" min.* | |
|
|
|
| (45.72 cm) | |
1" | 27" | 1" | 1"* | 32⁹⁄₁₆" | 5"** |
(2.5 cm) | (68.6 cm) | (2.5 cm) | (2.5 cm) | (82.65 cm) | (12.7 cm) |
AB
A. Recessed area
B. Side view - closet or confined area
*Required spacing
**For side or bottom venting, 2" (5.1 cm) spacing is allowed.
5