Whirlpool W10136968C manual Wire connection Direct wire

Page 10

1.Remove center silver-colored terminal block screw.

2.Remove neutral ground wire from external ground conductor screw. Connect neutral ground wire and the neutral wire (white or center wire) of power supply cord under center, silver-colored terminal block screw. Tighten screw.

A

C

B

D

 

E

A. External ground conductor screw - Dotted line shows position of NEUTRAL ground wire before being moved to center silver-colored terminal block screw.

B. Center silver-colored terminal block screw C. Neutral ground wire

D. Neutral wire (white or center wire) E. ¾" (1.9 cm) UL listed strain relief

3.Connect ground wire (green or bare) of power supply cord to external ground conductor screw. Tighten screw.

A

D

4-wire connection: Direct wire

IMPORTANT: A 4-wire connection is required for mobile homes and where local codes do not permit the use of 3-wire connections.

Direct wire cable must have 5 ft (1.52 m) of extra length so dryer can be moved if needed.

Strip 5" (12.7 cm) of outer covering from end of cable, leaving bare ground wire at 5" (12.7 cm). Cut 1¹⁄₂" (3.8 cm) from

3 remaining wires. Strip insulation back 1" (2.5 cm). Shape ends of wires into a hook shape.

1" .5cm) (2

5"

(12.7

cm)

 

When connecting to the terminal block, place the hooked end of the wire under the screw of the terminal block (hook facing right), squeeze hooked end together and tighten screw, as shown.

B

E

1.Remove center silver-colored terminal block screw.

2.Remove neutral ground wire from external ground conductor screw. Connect neutral ground wire and place the hooked end (hook facing right) of the neutral wire (white or center wire) of direct wire cable under the center screw of the terminal block. Squeeze hooked ends together. Tighten screw.

C

F

B

A

C

A. External ground conductor screw

B. Ground wire (green or bare) of power supply cord

C. ³⁄₄" (1.9 cm) UL listed strain relief

D. Center silver-colored terminal block screw

E. Neutral ground wire

F. Neutral wire (white or center wire)

4.Connect the other wires to outer terminal block screws. Tighten screws.

5.Tighten strain relief screws.

6.Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw.

7.You have completed your electrical connection. Now go to “Venting Requirements.”

D

E

A. External ground conductor screw - Dotted line shows position of NEUTRAL ground wire before being moved to center silver-colored terminal block screw.

B. Center silver-colored terminal block screw C. Neutral ground wire

D. Neutral wire (white or center wire) E. ¾" (1.9 cm) UL listed strain relief

10

Image 10
Contents Electronic Electric Dryer W10136968CTable of Contents Dryer SafetyTools andParts Installation InstructionsIf using a power supply cord Parts neededOptions LocationRequirementsCustom undercounter installation Dryer only Installation clearancesDryer Dimensions Closet installation Dryer onlyMobile home Additional installation requirements Recommended installation spacing for cabinet installationMobile home installations require It is your responsibility If connecting by direct wireElectricalRequirements Electrical ConnectionStyle 1 Power supply cord strain relief Power Supply Cord Direct WireElectrical Connection Wire connection Power supply cord Style 2 Direct wire strain reliefWire connection Direct wire Remove center silver-colored terminal block screwBDE CG F Optional 3-wire connection VentingRequirements If using an existing vent systemIf this is a new vent system Vent material Special provisions for mobile home installations Optional exhaust installationsAlternate installations for close clearances PlanVentSystemVent system chart Install VentSystemInstall LevelingLegs ConnectVentConnectInletHose CompleteInstallationLevelDryer StartingYourDryer Dryer USEIf the dryer will not start, check the following To use a Manual Cycle To use an Automatic CycleHow Automatic Cycles Work To use a Steam CycleControlLocked PausingorRestartingStopping YourDryer DryingandCycleTipsCycles Additional Features ChangingCycles,Options andModifiers DryingRackOptionCleaningtheDryerInterior CleaningtheDryer LocationCleaningtheLintScreen Dryer CareVacation,StorageandMovingCare RemovingAccumulatedLintWaterInletHoses ChangingtheDrumLightDryerOperation TroubleshootingDryerResults Stains on load or drum Cycle time too shortLint on load Loads are wrinkledAccessories Call W10136968C