Emotiva USP-1 manual Connecting To Amplifiers and Speakers, Tape, Ht Input, Trigger Connections

Models: USP-1

1 26
Download 26 pages 53.22 Kb
Page 17
Image 17

TAPE

This ‘loop’ connects an external recording device to the USP-1 preamplifier via RCA outputs and inputs. While this traditionally has been a cassette player or DAT player, this connection could also be a hard drive based recording device as long as the input and output connections are analog RCA audio connections.

To enable the tape monitor loop you must connect to the inputs AND outputs on the USP-1 labeled

"TAPE" on the rear panel. To engage the tape monitor loop, select TAPE from the USP-1 front panel or remote.

Please note -these outputs are unaffected by any external signal processing.

To engage the recording device, first press TAPE from the front panel or remote and then it will allow you to “monitor” the audio that the recording device will record. When you are ready to record, engage the recording device.

HT INPUT

Connects to an external multi-channel, or ‘home theater’ processor using standard RCA type analog connectors. Connect left, right, and subwoofer (if your front speakers are not full range) analog outputs on the processor to the USP-1 HT inputs. When the HT BYPASS button is selected, all USP-1 functions are disabled, and it becomes a pass-through for the connected external processor. The HT inputs are only active when the USP-1 is on.

Connecting To Amplifiers and Speakers

When connecting to amplifiers and speakers, make sure to use the properly labeled left channel, right channel and subwoofer connections.

Check to make sure that you have connected the proper cables in the proper sequence:

1)Left and right channel USP-1 outputs (either full range or High Pass) into left and right channel amplifier inputs. 2) Left and right channel amplifier outputs to left and right speakers.

3)USP-1 subwoofer outputs for powered subwoofer inputs.

NOTE: Do not connect speakers directly to the USP-1.

Also use high quality, 100% shielded, oxygen free copper cables.

Trigger Connections

12VDC trigger used to remotely trigger a connected device on and off. Please ensure that the total of the loads connected to this trigger do not exceed 500mA.

17